Place the reference weight, 55 to 72 lbs (28 to 32 kg) at the center of the scale plate. Use keys
0 through 9 to type in the value of the weight. Press START. Switch off the machine and
disconnect it from mains supply. Replace the bottle on the scale plate and the heating coil on
the bottle ensuring that the heater adheres tightly to the bottle). Replace the plastic cover.
Open the blue and red taps on the bottle and hoses. Replace the rear plastic cover.

BOTTLE DATA

NOTE: This menu is reserved for use by the technician performing final testing. It contains the
maximum safety threshold value; therefore, the bottle data may not be changed for any reason.
For assistance, call the Service Center.
Access the CALIBRATION MENU as explained above.
The following screen will be displayed:
With the BOTTLE SCALE message flashing, press the ENTER key. The following screen will
be displayed:
Select BOTTLE DATA. The following screen will be displayed:
Use the arrow keys and the numerical keypad to change the Max, Min, and Tare values. Then
select PREVIOUS MENU and press ENTER.
Press START to confirm saving the data or STOP to exit without saving.

BOTTLE PRESSURE TRANSDUCER

Remove the rear plastic cover of the machine to access the bottle. Close the blue tap on the
bottle and the tap under the high-pressure filter (3, Fig.11). Slowly unscrew the blue hose from
the bottle to bring the pressure in the bottle transducer to zero. Switch the machine on.
Access the CALIBRATION MENU as explained above.
The following screen will be displayed:
INSTRUCTIONS MANUAL
REFERENCE VALUE
x:xx lb
Levels
xxxxx
Press START
<BOTTLE SCALE >
BOTTLE PRESSURE TR.
BOTTLE TEMPERATURE
PREVIOUS MENU
CALIBRATION
<BOTTLE DATA>
PREVIOUS MENU
Min
x,xx lb
Tare
x,xx lb
PREVIOUS MENU
SAVE DATA:
Press START.
To exit:
press STOP
-19-