Select BOTTLE PRESSURE TR and press the ENTER key. The following screen will be
displayed:
Press START to ZERO.
BOTTLE TEMPERATURE
NOTE: A digital thermometer is required for bottle temperature sensor calibration. Check that
the bottle temperature probe is disconnected from the bottle and so capable of reading the
ambient temperature.
Enter the CALIBRATION MENU as explained above.
The following will be displayed:
Select BOTTLE TEMPERATURE and press the ENTER key to confirm:
Check that the temperature shown on the display is that also read on the external
thermometer. If necessary, press START to modify the machine value:
Type in the temperature read on the digital thermometer and press ENTER to confirm.
Replace the temperature probe on the bottle.
SETTINGS
LANGUAGE
Switch the machine on. The MAIN MENU will appear after a few seconds:
INSTRUCTIONS MANUAL
BOTTLE SCALE
<BOTTLE PRESSURE TR.>
BOTTLE TEMPERATURE
PREVIOUS MENU
ZERO LEVEL
Unscrew blue hose
Levels
xxxxx
Press START
BOTTLE SCALE
BOTTLE PRESSURE TR.
<BOTTLE TEMPERATURE>
PREVIOUS MENU
BOTTLE TEMPERATURE
XX.X °F
START to calibrate
STOP to exit
BOTTLE TEMPERATURE
XX.X °F
XXX.X °F
Press START
-20-