PRINCIPLES OF OPERATION
In a single series of operations, the machine permits recovering and recycling refrigerant with
no risk of release into the environment, and also permits purging the A/C system of humidity
and deposits contained in the oil. The machine is equipped with a built-in evaporator/separator
that removes oil and other impurities from the refrigerant recovered from the A/C system and
collect them in a container for that purpose. The fluid is then filtered and returned perfectly
recycled to the bottle installed on the machine. The machine also permits running certain
operational and leak tests on the A/C system.
SETUP
The machine is supplied fully assembled and tested. Referring to Figure 3, mount the hose
with the BLUE quick-connect coupling on the male threaded connector indicated by the BLUE
LOW PRESSURE symbol and the hose with the RED quick-connect coupling on the male
threaded connector indicated by the RED HIGH PRESSURE symbol. Referring to Figure 4,
remove the protection under the refrigerant scale as follows:
-
Loosen the nut [2].
-
Completely loosen the screw [1].
-
Keep the screw [1], the nut [2], and the knurled washer [4] for possible future use.
NOTE: In the event that the equipment has to be transported; the refrigerant bottle scale
should be locked in place as follows:
-
Use two size 10 wrenches.
-
Tighten the nut [2] almost completely onto the screw [1].
-
Insert the knurled washer [4] onto the screw [1].
-
Turn the screw [1] just a few times on the threaded bush [6].
-
Switch the machine on.
-
Tighten the screw [1] until the display signals ZERO availability.
-
Tighten the nut [2] forcefully (using the second wrench to block the screw [1]).
-
Check that the screw [1] is actually locked, if necessary repeat the locking operation
from the beginning.
THE MACHINE
BASIC COMPONENTS
Refer to Figures 5, 6, 7 and 8.
a) Control console
h) Wheels
m) Used oil container
e) Dryer filters
c) Moisture indicator
i) Main switch
k) Fuse
CONTROLS AND CONTROL SYSTEM
Refer to Figure 9.
A1) High pressure gauge
A3) Keyboard
FUNCTION SELECTOR KEYBOARD
STOP: Press to interrupt the operation being performed --recovery - oil discharge - vacuum/oil
charging - charging. Press START to resume operation from the point of interruption. Pressing
STOP during an alarm state, error state, or end-of-operation state silences the audible alarm.
INSTRUCTIONS MANUAL
f) Vacuum pump
b) Taps
l) High/Low Pressure threaded connectors
n) New oil container
d) Bottle
o) Electronic scale
ps) Serial port
j) Socket for electrical supply plug
r) Bottle heater
A2) Low pressure gauge
A4) LCD: 4 lines, 20 characters