INSTALLATION INSTRUCTIONS
4 WIRE POWER CORD INSTALLATION
The neutral wire of the supply circuit must be
connected to the neutral terminal located in the
lower center of the terminal block. The power
leads must be connected to the lower left and the
lower right terminals of the terminal block. The 4th
grounding lead must be connected to the frame of
the range with the ground plate and the ground
screw.
1. Remove the three lower terminal screws from the
terminal block.
2. Remove the ground screw and ground plate and
retain them.
3. Cut and discard the ground strap. Do not
discard any screws.
4. Insert the one ground screw into the power cord
ground wire terminal ring, through the ground
plate and into the frame of the range.
5. Insert the three terminal screws that were
removed earlier through each power cord
terminal right and into the lower terminals of the
terminal block.
6. Be certain that the center wire is connected to
the center lower position of the terminal block.
7. Tighten the screws securely into the terminal
block.
Before
1. Terminal block
2. Ground strap
3. Neutral terminal
4. Cut and discard the ground strap
1
4
After
1. Terminal block
2. Neutral terminal
3. Ground plate (grounding to range)
4. Ground screw
1
4