The power cable should be disconnected by one of two
methods. Either a plug socket combination that is
interlocked with a combined switch or a fixed
disconnect that provides relief from mechanical strain
on connection points should be used. Both methods
must comply with the authority having jurisdiction at
Voltage Designation
N
440 – 480
P
380 – 415
135
Q
200 – 240
N
440 – 480
250
P
380 – 415
Q
200 – 240
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
F232102
Cabinet Freestanding
Electrical Specifications
50-60
3
3
15
50-60
3
3
15
50-60
3
3
29
50-60
3
3
28
50-60
3
3
32
50-60
3
3
56
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
the point of installation and/or the National Electric
Code, article 400-5, EN60204 section 15.4.3. The
service disconnect mechanism should be between
2 and 6 feet (0.6 to 1.9 m) above the floor and should
be easily accessible.
Standard
30
10
3x4
30
10
3x4
60
6
3x16
40
8
3x10
40
8
3x10
70
6
3x16
Table 6
Installation
Electric Heat
78
95
4
78
95
4
N/A
N/A
N/A
N/A
3x25
3x25
33