Technical Specifications - APRITECH GTM Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 28
The GTM automated system for gates with swing leaves is an opera-
tor which transmits movement to the leaf via a worm screw system.
A handy release system makes it possible to move the gate ma-
nually in the event of a power cut or operator faults.
The operator is available in both the 230V version and in the 24V
version.
Before you start installing the operator, read this manual to
the letter.
Store the manual for any future references.
Correct operation and the declared technical characteristics
can be obtained only by respecting the indications in this
manual and using APRITECH accessories and safety devices.
To ensure an adequate degree of safety for the automated
system, the absence of a mechanical clutch device, calls for
the use of a control unit with an adjustable electronic clutch
device.
The GTM operator was designed and built to control vehicle
access – AVOID ANY OTHER USES.
Anything not expressly specified in this manual is not permitted.
1. DESCRIPTION
a Operator
b Transmission pipe
c Release key
d Rear fastening bracket
e Front fastening bracket
f Fastening pins
g Elastic rings

1.1. TECHNICAL SPECIFICATIONS

Model
Power suply voltage
and frequency
Absorbed power
Absorbed current
Thermal protection
Capacitor
Max.thrust force
Rod stroke
Rod linear speed
Operating ambient temperature
Type and use frequency
a
Indicative hour cycles at 20°C
Operator weight
Protection class
Maximum leaf length
b
To calculate use frequency, refer to paragraph 1.1.1.
a
For leaves of over 2.5 m, an electrical lock is necessary to
b
guarantee leaf blocking
GTM AUTOMATED SYSTEM
Fig. 1
GTM
GTM 24V
230Vac 50Hz
24Vdc
280 W
70W
1.2 A
3 A
140 °C
8µF 400V
350 daN
300 daN
300 mm / 400 mm
1.6 cm/sec
-20 °C — +55°C
S3 30%
Intensive
≥30 (≥24)
≥100 (≥75)
6.5 Kg / 7Kg
IP 54
3 m /4 m
1.1.1. G
raph and use frequency
The curve makes it possible to establish maximum work time (T)
according to use frequency
(F).
With reference to standard
IEC 34-1, the GTM gearmo-
tor, with service type S3, can
operate at use frequency
of 30%.
To ensure efficient operation,
operate in the work range
under the curve.
The curve is obtained at
a temperature of 20°C.
Exposure to direct sun
rays can reduce use
frequency down to 20%.
c
alculation of use frequency
The percentage of effective work time (opening + closing) com-
pared to total time of cycle (opening + closing + pause times).
Calculation fomula:
Ta + Tc
% F = ––––––––––––––––––– X 100
Ta + Tc + Tp + Ti
Where:
Ta =
opening time
Tc =
closing time
Tp =
pause time
Ti =
interval time between one complete cycle and another
1.2. DIMENSIONS
7
Fig. 2

Publicidad

Capítulos

Tabla de contenido
loading

Productos relacionados para APRITECH GTM

Este manual también es adecuado para:

Gtm 24v

Tabla de contenido