Care And Maintenance; Care And Maintenance Instructions - Chicago Faucets E-Tronic 20 Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Chicago Faucets E-Tronic

CARE AND MAINTENANCE

INSTRUCTIONS
The following instructions are described in this section:
• Replacing Battery
• Cleaning or Replacing Inlet Filter
• Adjusting Water Temperature (Internal Mixer)
• Cleaning or Replacing Aerator
Replacing Battery
These instructions apply to all DC models.
Prerequisites
• Battery is low (LED is lit)
• New 6 V Lithium battery (CR-P2) is required
1
Remove shut-off screw
2
Remove housing vertically
3
Remove used battery from battery holder and recycle
20 User Guide
Insert new battery
4
> LED lights up for 1 second
5
Mount housing vertically
6
Install shut-off screw
Result
The battery is now replaced.