Storage of a transmitter key with enabling of a bistable "Service Light"
- Press the PU2 key once for 1s, the LD1 LED emits 1 flash with 1s pause.
- Press the PU2 key again 3 times, the LD1 LED will flash 4 times with 1s pause
- Press the transmitter key to be stored with the bistable "Service Light" function within 10s, the 3 red LEDs light up for 1s then, after
storing, the receiver automatically exits the programming phase.
The "Service Light" is enabled or disabled each time the stored key is pressed.
Remote acquisition of a transmitter
If you already have a stored transmitter, others can be stored without accessing the control panel. Remote storage must be performed
with the panel completely open, regardless of the TCA setting. Proceed as follows:
1 Press the hidden key of the stored transmitter.
2 Press the key of the stored transmitter to be copied within 10s. The "Service Light" flashes.
3 Press the hidden key of the new transmitter to which the function is to be associated within 10s.
4 Press the key of the new transmitter to which you want to associate the function selected in point 2 within 10s. The "Service Light" is
steady.
5 The new transmitter has been stored, the receiver exits the programming phase.
E.g.: key 1 of TX "A" contains the P.P. function that you want to assign to key 2 of the new TX "B"; press in sequence:
hidden key of TX A >> key 1 of TX A >> hidden key of TX B >> key 2 of TX B.
Deleting all transmitters from memory
- Keep the PU2 key pressed for 15s, the LD1 / 2/3 LEDs and the service light start flashing quickly and turn off when cancellation is
complete.
- Release the PU2 key, the memory has been erased.
PLEASE NOTE:
Transmitters may not be stored during the opening/closing phases of the motor due to safety reasons.
Today, KNX is the open global standard, compliant with the main European and international standards, allowing the automated and
decentralized management of technological systems of a wide range of structures: commercial buildings, industries, offices, homes,
public premises, schools and many more.
This product is compatible with KNX standard and can be connected to a KNX network using the optional X.BE accessory.
For further information, please refer to the instructions supplied with the X.BE.
This procedure takes the control panel back to factory default conditions.
CAUTION: All stored transmitters are also deleted.
Total reset procedure:
- Disconnect from the mains
- Press and hold PU1 + PU2 keys
- Connect to the mains
- Wait for LD1 / LD2 / LD3 LEDs to turn ON in sequence, total reset is now complete.
LEDs LD1 / 2/3 in normal operation give a number of indications:
LD1
Slow flashing:
1 flash with pause:
2 flashes with pause:
3 flashes with pause:
4 flashes with pause:
5 flashes with pause:
These indications are also signalled for about 10s by the service light, at the end of movement.
LD2
on: motor at end-of-run CLOSING
LD3
on: motor at end-of-run OPENING
LD1+LD2+LD3
simultaneous flashing:
IKNX COMMUNICATION INTERFACE
Mains supply present, no input active
STOP input active (contact open)
Photocell input active (contact open)
S.S. Input active
Encoder Error
Amperometric sensor intervention
AUTOSET error or transmitter memory error (memory full).
TOTAL RESET

LED DIAGNOSTICS

13