3.6 Connection example valve terminal type 10
1
AS−Interface master
2
Combination power
supply from Festo
(electronically safe
guarded/short−
circuit proof )
3
Load voltage can
be switched off
3.7 Converting the valve terminal
The CPV valve terminal can be fitted with double−solenoid
and/or single−solenoid valves. During conversion, the new
valve terminal configuration must be set on the DIP
switches on the bottom of the electric sub−base.
1
DIP switch 1:
Valve locations
1 to 4 (slave 1)
2
DIP switch 2:
Valve locations
5 to 8 (slave 2)
Instructions on removign the electric sub−base can be
found in the Pneumatics Manual. The permitted valve com
binations as well as the relevant DIP switch settings can be
found in the table in section 3.3.
24
1
2
3
1
Festo CPV..−GE−ASI−8E6A−Z 0802a English
0
1
2
3
4
5
6
7
2

Publicidad

loading

Este manual también es adecuado para:

Cpv ge-asi-8e6a-z m8 serie