PLACING THE MACHINE IN SERVICE
LUBRIFICATION
Always use an air line lubricator with these machine. We recommended the
following Filter-Lubricator-Regulator Unit: USAG 930.
Every eight hours' operation, if a lubricator is not used on the compressed air
network, inject 1/2 to 1cm
3
through the machine's inlet connection.
Model
Square
Impact
drive
rate
''
942 PB1
3/8
1750
942 PC2
1/2
1750
Model
Free speed
rpm
942 PB1
10500
942 PC2
10500
* k = measurement uncertainty in dB
SWK Utensilerie S.r.l., Sede Operativa VIA VOLTA 3 - 21020 - MONVALLE (VA) ITALY, DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE PRODUCT
942 PB1 – USAG 3/8" AIR IMPACT WRENCH , 942 PC2 – USAG 1/2" AIR IMPACT WRENCH
- IS IN CONFORMITY WITH THE «MACHINERY» DIRECTIVE 2006/42/CE
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN STANDARD EN 792-6 :2000 +A1:2008
BS EN ISO 12100-1:2003+A1:2009
BS EN ISO 12100-2:2003+A1:2009
EN ISO 15744:2008
EN 28662-1:1993 &BS EN ISO 28927-2:2009
• BEFORE EACH OPERATION, CHECK:
- Only use suitable USAG sockets and flogging spanner accessories, (''IMPACT'') as well as
safety devices, bush and pin for mounting one of these cases on a drilled driving
square.
- The drive square condition (no marks, cracks or excessive wear).
- The condition of the safety devices (bush and pin) on the drilled square as well as the draw
bead on the non-drilled square.
Maximum
dynamic
Pressure dB(A)
torque
N.m
k*
710
93,8
1,5
800
93,8
1,5
Air consumption
Working pressure
l/min
bar
125
6,2
125
6,2
** k = measurement uncertainty in m/s²
CE DECLARATION OF CONFORMITY
CE DECLARATION OF CONFORMITY
EMERGENCY
GATE VALVE
Noise level
Power dB(A)
Pressure dB(C)
k*
104,8
1,5
99,5
1,5
104,8
1,5
99,5
1,5
Weight
Dimensions
kg
mm
1,3
152x67x181
1,4
157x67x181
Vibrations
level
m/s
2
k*
k**
3,06
0,79
3,06
0,79
20.10.2011
U
SAG QUALITY MANAGER