HAMPTON BAY Windward IV Manual Del Propietário página 7

Ocultar thumbs Ver también para Windward IV:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

UL Listed
Outlet Box
Slide Mounting
Plate Over
Screw Heads
120V Wires
Canopy
Canopy Ring
Downrod Cover
Motor Collar Cover
Hanger Pin
Reversing
Switch
6. Re-tighten the set screws on the collar on top
of the motor housing (Figure 8).
7. Proceed to "Installing the Fan" section.
Mounting
Screws
(Supplied With
Outlet Box)
Hook
"Close-to-Ceiling" Mounting
Ceiling
1. Remove canopy ring from the canopy by
Mounting
turning the ring to the right until it unlocks
Plate
(Figure 5).
2. Remove the mounting plate from the canopy
Motor Wires
by loosening the four screws on the top of the
Downrod/Ball
canopy. Remove the two non-slotted screws
Assembly
and loosen the slotted screws. This will enable
you to remove the mounting plate (Figure 6).
Pin in
3. Remove the decorative canopy bottom cov-
Locked
Position
er from the canopy by depressing the three
studs (Figure 9).
Locking Pin
Figure 7
Canopy
Bottom
Cover
4. Remove three of the six screws and lock
Tighten Set
washers (every other one) securing the mo-
Screw
tor collar to the top of the fan motor housing
(Figure 10).
5. Place
the
Figure 8
remaining three screws, route the wires
exiting the top of the fan motor through the
canopy ring (make sure the slot openings
are on top), then proceed to place the ceiling
canopy over the collar at the top of the motor
(Figure 11).
6. Align the mounting holes with the holes
in the motor and fasten, using the three
screws and lock-washers removed in
step 4 (Figure 11).
7. Tighten the mounting screws securely.
FAILURE TO COMPLETELY TIGHTEN THE
THREE SCREWS IN STEP 7 COULD RESULT IN
FAN LOOSENING AND POSSIBLY FALLING.
Motor Collar
Figure 9
rubber
gasket
over
the
Screw and
Lockwasher
(3 of 6 screws)
Figure 10
5.

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido