I Step 4 - Programming radio or hardwired operating mode
RADIO OPERATING MODE
Operation made
Entering the programming
menu for
the radio type used
If the transmitter is connected to a TwinPass
control panel or radio transmitter
Drop-down menu shown Steps to be followed
System code ?
–
HARDWIRED OPERATING MODE
Operation made
Entering the programming
menu for
hardwired inputs
Choosing the hardwired
input to be programmed
If the hardwired input is used as a hardwired detector
Drop-down menu shown
Input triggering
On close & open
Time Filtr: mmss's
– – – – –
5 calls maximum
– –
ContactID code
380
Drop-down menu shown
Programming
Wireless format
Wireless format
Twin pass type
• Programme the 10-digit installation
code (0 and 1)
• Press (OK) to validate
Drop-down menu shown
Programming
Inputs prog
Inputs prog
Inp1
Inp1
NC
E1
Sensor
Steps to be followed
• Choose between Active/Rest (the phone
call is made every time the input
status changes) or Active (the phone
call is made only when the input is acti-
vated)
• Press (OK) to validate
• Programme the Filtering time for the
input: this time corresponds to the time
needed for the dialler to take into account
any change in the status of this input.
• Press (OK) to validate
• Choose call memories allocated
to the hardwired inpu
• Press (OK) to validate
• If necessary, change the remote surveillance
code transmitted with Contact ID protocol
If the phone call is made
in vocal mode, ignore this
drop-down menu
• Press (OK) to validate
Steps to be followed
• Press (OK) to validate
to choose between Twin pass type or Twin band type
• Use keys
L M
• Press (OK) to validate
®
If the transmitter is connected to a TwinBand
Drop-down menu shown Steps to be followed
Press * on Panel
...
Save ?
Steps to be followed
• Press (OK) to validate
• Choose an input from E1 to E4 (from E1 to E8 for model G450-30X
fitted with a 901-21X adapter only) by using keys
• Press (OK) to validate
• Choose the type of contact (NO or NF) for the input by using keys
• Press (OK) to validate
• Choose the type of application by using keys
- Sensor for all Sensor connections
- Arm/Disarm input if the hardwired input is used to validate
other hardwired inputs. In this case, the state of this input conditions
whether or not the other inputs connected are taken into account or not.
- Tel line failure If a telephone line breakout module (905-21X)
is connected and the GSM transmitter supports the
transmitter via the RTC line.
• Press (OK) to validate
If the hardwired input is used to validate other hardwired inputs
Drop-down menu shown
Time Filtr: mmss's
– – – – –
5 calls maximum
– –
Please refer to the installation manual
for the list of codes.
37
control panel or radio transmitter
• press and hold the "OFF" or "
the control panel keypad (or associated
control interface), or the stop key
of a controller, or the test key of the
detector until this message is displayed
• Press (OK) to validate
L M
among:
L M
or to detect telephone line breakout
Steps to be followed
• Programme the Filtering time for the input:
this time corresponds to the time needed
for the dialler to take into account any
change in the status of this input.
• Press (OK) to validate
• Choose call memories allocated
to the hardwired input
• Press (OK) to validate
G
®
" key on
*
L M