ENGLISH
TraceAll
The Klein Tools TraceAll™ Tone & Probe is a portable device that assists in
tracing. It includes a tone generator that places a low voltage signal on the
line, and a tracer that detects and amplifi es the signal.
•
Dimensions:
5.0 oz. (140 grams) with battery and remote
•
Weight:
•
Operating Temperature:
•
Storage Temperature:
•
10% to 90%, non-condensing
Humidity:
•
Externally Applied Voltage
•
DC:
250V
•
AC:
175V RMS
•
Battery Life
•
Tracer:
•
Generator:
•
Tone Voltage:
•
Tone Power:
•
Tone Frequencies:
•
Probe Replacement Tip:
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Connecting the TraceAll™ to live AC power may damage it and pose a
safety hazard for the user.
• Poorly terminated RJ plugs have the potential to damage the jack on
the TraceAll™. Visually inspect a RJ plug before inserting it into the
generator. The contacts should always be recessed into the plastic
housing of the plug.
WARNINGS:
Always wear approved eye protection.
Do NOT use on energized circuits.
2
Tone & Probe
™
Instruction Manual
GENERAL SPECIFICATIONS
8.9" x 1.7" x 1.2" (22.6 x 4.3 x 3.0 cm)
0°C/32°F to 50°C/ 122°F
-20°C/-4°F to 60°C/140°F
without damage:
(typical): 6V – 4 x LR44 alkaline batteries
10 hours
50 hours
12 volts peak-to-peak no load, new battery
8.9 dBm into 600 ohms, new battery; 7.2dBm average
1116Hz and 919Hz ±5%
Cat No. VDV999-058
WARNINGS
WARNINGS