5. Using a thermometer, test the mixed water temperature at the nearest out-
let being supplied by the valve. This should be opened to allow a minimum
flow rate of 1.5 gpm (6 L/min). Allow the water to run for at least one minute
to ensure the mixed water temperature has settled.
Thermo-strip
The thermo-strip included in this kit may be used to indicate the outlet tempera-
ture of the mixing valve to the household.
It shall not be used to set the outlet temperature of the mixing device; this must
be performed as stated in the temperature setting instructions.
To install the thermo-strip, remove the adhesive backing and apply the thermo-
strip to the mixing valve outlet pipe-work no less than 10" from the outlet con-
nection.
TANK BOOSTER
Installation Instructions
IS279 REV L
2-17-16
14