4.8 End of programming
5. Technical data
Supply voltage
AC power supply:
DC power supply:
Display:
Data retention:
Polarity of the inputs:
Input resistance:
Count frequency:
AC power supply: 90 ... 260 V AC
Input level:
typ. low level:
typ. high level:
Fmax:
tot.tac
tot.tot
tot.ti 1)
tot.ti 2)
1) Start Gate.Lo Inp B not activ
2) Start InpB.InpB and Inp B connected
with Inp A
The programming routine
is repeated once more.
The values set until now
can be checked and mod-
ified.
The programming routine
wil be left and all values
set will be stored as new
parameters.
Afterwards the device is
ready for operation.
90 ... 260 V AC/max. 6 VA
10 ... 30 V DC/max. 50 mA
with inverse-polarity protection
6 digits, red 7 segment
LED display, height 14 mm
EEPROM
Programmable, npn or pnp
for all inputs
appr. 5 kΩ
standard
5V
2,5 V
1,0 yp.
22,0 V
4,0 V
kHz
kHz
35
35
60
50
35
30
15
15
DC power supply:
24 12 V DC 10 ...30 V DC
Input level:
Standard
typ. low level:
2,5 2,0 V
typ. ligh level:
22,0
Fmax:
kHz kHz
tot.tac
35
tot.tot
60
tot.ti 1)
40
tot.ti 2)
15
1) Start Gate.Lo Inp B not activ
2) Start InpB.InpB and Inp B connected
with Inp A
Frequency measurement:
Accuracy :
< 0.1 %
Measuring principle:
< 38 Hz:
period measurement
> 38 Hz:
gating time measurement
gating time = 26,3 ms
Time count ranges:
Seconds
0,001 s ... 999 999 s
Minutes
0,001min ... 999 999 min
Hours
0,001 h ... 999 999 h
h.min.s
00 h 00 min 01 s
... 99 h 59 min 59 s
Accuracy
<50 ppm
Minimum pulse length for the Reset input:
5 ms
Input sensitivity:
Standard sensitivity:
AC power supply
Low: 0 ... 4 V DC
High: 12 ... 30 V DC
DCpower supply
Low: 0 ... 0,2 x U B [V DC]
High: 0,6 x U B ... 30 [V DC]
5 V sensitivity:
Low: 0 ... 2 V DC
High: 4 ...30 V DC
Pulse shape:
any,
Schmitt-Trigger inputs
Sensor supply voltage:
AC version
24 V DC ±15 %/100 mA
Ambient temperature:
–20 ...+65 °C
Storage temperature:
–25 ... +70 °C
5V
1,0 V
10 V
4,0 V
kHz
20
8
20
8
20
8
10
8
23