Adjusting the switching behavior of the switching output – light/dark
switching
This function permits inversion of the label sensors' switching logic.
4
A The green LED flashes at 3 Hz
B Yellow LED ON: switching outputs light switching
C Yellow LED OFF: switching outputs dark switching
D Teach button
Ä
Press teach button until only the green LED flashes (A). The yellow LED then
indicates the inverted switching logic.
Yellow LED ON (B): switching outputs light switching
– Switching output active if object is detected
– In the case of antivalent label sensors: Q1 (pin 4) light switching, Q2 (pin 2)
dark switching
Yellow LED OFF: switching outputs dark switching
– Switching output inactive if object is detected
– In the case of antivalent label sensors: Q1 (pin 4) dark switching, Q2 (pin 2)
light switching
Changing the switching logic (D):
Ä
Press the teach button longer than 12 s.
Ä
Release teach button.
EN
11