Operation; Grounding The Generator; How To Start Engine - Pulsar HD6580B Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Grounding the Generator (See fig 7)
The ground terminal located on the front panel of the generator may be used for additional grounding,
or when connected to a structure. Connect the ground terminal to an earthen ground rod, driven six
feet into the ground. with a No 8 AWG (American Wire Gauge) copper wire. The wire connects to the
terminal between the lock washer and nut. Tighten the nut securely to ensure proper connection.
Grounding thegenerator protects you from electric shock that results from a build up of static electricity
or undetected ground faults.
How to Start Engine (See fig 8-12)
• Place generator on a level surface. All electrical loads MUST be disconnected from generator.
When Using Gasoline
• Turn fuel valve to the "ON" position. (See fig 9)
• Slide the choke lever to the "Choke" position. (See fig 10) SKIP THIS IF THE ENGINE IS WARM OR HOT.
• Push the ON/OFF switch to the "ON" position. Pull the recoil handle (starter cord) slowly until resistance is felt, return,
then pull rapidly. (See fig 11)
• Let engine run for several seconds and then gradually, as engine warms up, slide the choke lever towards the "RUN"
position until the choke is fully engaded to the "RUN" position. (See fig 12)
When Using LPG
• Connect the propane hose to the intake nozzle of regulator; Open the valve on the LPG tank
Slide the choke lever to the "Choke" position. (See fig 10) SKIP THIS IF THE ENGINE IS WARM OR HOT.
Push the ON/OFF switch to the "ON" position. Pull the recoil handle (starter cord) slowly until resistance is felt, return,
then pull rapidly. (See fig 11)
Let engine run for several seconds and then gradually, as engine warms up, slide the choke lever towards the "RUN"
position until the choke is fully engaded to the "RUN" position. (See fig 12)
It is very important to SHUT OFF the fuel supply and wait for the generator to stop running before switching fuel source.
Gasoline to Propane:
1. With the generator running, turn the gasoline supply valve 90 degrees to shut off flow; then wait (up to 2 minutes) for
the machine to stop on its own.
2. With the generator and gasoline supply now OFF and propane hose properly connected, open the propane supply by
turning the supply valve fully left, wait 30 seconds, then start the generator.
Propane to Gasoline:
1. With the generator running, turn the propane supply valve fully right to shut off flow; then wait (up to 30 seconds) for
the machine to stop on its own.
2. With the generator and propane supply now OFF, turn gasoline supply valve 90 degrees, (straight up and down) wait
2 minutes, then start the generator.
CAUTION
!
CAUTION! Failure to follow this process may cause rough operation which could lead to engine damage
Fig 8

OPERATION

IMPORTANT NOTICE FOR SWITCHING FUEL SOURCES
CHOKE
CHOKE LEVER
Fig 9
SKIP THIS IF THE ENGINE IS
RUN
1
Fig 10
Fig 11 Recoil Start
WARM OR HOT.
12
(See fig 8)
CHOKE
CHOKE LEVER
START
ON
2
OFF
Fig 7
WAIT
5sec
RUN
Fig 12

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido