1. WARNINGS
Before attempting any work on the control board (connections, maintenan-
ce), always turn off power.
Install, upstream of the system, a differential thermal breaker with adequate
tripping threshold.
Connect the earth cable to the appropriate terminal on the J7 connector
of the equipment (see fig.2).
Always separate power cables from control and safety cables (push-but-
ton, receiver, photocells, etc.). To avoid any electric noise, use separate
sheaths or a shielded cable (with earthed shield).
2. TECHNICAL SPECIFICATIONS
Power supply (+6% -10% V)
Absorbed power
Motor max. load
Accessories max. load
Operating ambient tempe-
rature
Protection fuses
Automatic / "Stepped" automatic / Semi-au-
tomatic / Safety devices / Semi-automatic B
Function logics
/ Dead-man C / "Stepped" semi-automatic
Work time
Pause time
Thrust force
Open / Pàartial opening / Safety devices
Terminal board inputs
at opng. / Safety devices at clsng. / Stop /
Opening and closing limit-switches / Enco-
On-connector inputs
Flashing lamp - Motor - 24 Vdc accessories
Terminal board outputs
power supply - 24 Vdc indicator-light / Timed
5-pin card connection for Minidec, Decoder
Rapid connector
Programming
Basic mode programmable
Function logic - Pause time - Thrust Force
functions
Torque at initial thrust - Braking - Fail safe
- Pre-flashing - Indicator-light/Timed output -
Advanced mode program-
Opening and closing safety devices logic -
mable functions
Encoder - Decelerations - Partial opening
time - Work time - Assistance request - Cycle
CONTROL BOARD 740 D
230 V~ - 50 Hz
(115 V~ - 60 Hz*)
10 W
(10 W*)
1000 W
(1200 W*)
0,5 A
(0.5 A*)
-20 °C +55 °C
2 (see fig. 1)
/ Mixed Log. B+C
Programmable (from 0 to 4 min.)
Programmable (from 0 to 4 min.)
Adjustable over 50 levels
Edge / Power supply + Earth
der
output. - Fail safe
or RP receivers
3 keys (+, -, F) and display, "basic" or
"advanced" mode
- Gate direction
counter
4. ELECTRIC CONNECTIONS
3. LAYOUT AND COMPONENTS
DL
SIGNALLING AND PROGRAMMING DISPLAY
Led
INPUTS STATUS CONTROL LED
J1
LOW VOLTAGE TERMINAL BOARD
J2
CONNECTOR FOR DECODER/MINIDEC/RP RECEIVER
J3
ENCODER CONNECTOR
j4
CAPACITOR CONNECTOR
J5
LIMIT -SWITCH CONNECTOR
J6
MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD
POWER SUPPLY TERMINAL BOARD 230Vac (115Vac*)
J7
F1
MOTORS AND TRANSF. PRIMARY FUSE (F 5A) (F 10A*)
F2
LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
F
"F" PROGRAMMING PUSH-BUTTON
-
"–" PROGRAMMING PUSH-BUTTON
+
"+" PROGRAMMING PUSH-BUTTON
* 740D 115V
12
Fig. 1
Fig. 1
C
J4
*
115 Vac
max 60w
230 V ~ / 50 Hz
(According to
or
the selected
115 v ~ / 60Hz
control unit)
(According to
the selected
control unit)
* Only if don't use J4 connector
* Only if don't use J4 connector
Fig. 2
Fig. 2