5. PROGRAMMING
To program operation of the automated system, you have to access the
"PROGRAMMING" mode.
Programming is split into two parts: BASIC and ADVANCED.
5.1. BASIC PROGRAMMING
To access BASIC PROGRAMMING, press key F:
•
if you press it (and hold it down), the display shows the name of the first
function.
•
if you release the key, the display shows the value of the function that can
be modified with keys + and -.
•
if you press F again (and hold it down), the display shows the name of
the next function, etc.
•
when you reach the last function, press F to exit the program, and the
display resumes showing the gate status.
The following table shows the sequence of functions accessible in BASIC
PROGRAMMING:
BASIC PROGRAMMING
Display
Function
FUNCTION LOGICS (see tab. 3/a - h):
A
=Automatic
AP
="Stepped" automatic
S
= "Safety" Automatic
LO
E
= Semi-automatic
EP
= "Stepped" Semi-automatic
C
= Dead-man
b
= "B" Semi-automatic
bC
b
= Mixed Log. (
PAUSE TIME:
This has effect only if the automatic logic was
selected. Adjustable from
second steps.
Subsequently, display changes to minutes and
PA
tens of seconds (separated by a point) and time
is adjusted in 10-second steps, up to the maximum
4.1
value of
minutes.
E.g. if the display shows
and 50 sec.
FORCE:
Adjusts Motor thrust.
F0
01
= minimum force
50
= maximum force
OPENING DIRECTION:
Indicates the gate opening movement and
makes it possible not to change the motor and
d1
limit-switch connections on the terminal board.
-3
= Right-hand opening movement
E-
= Left-hand opening movement
GATE STATUS:
Exit from programming and return to gate status
viewing.
00
= Closed
01
= Now opening
02
= Stopped
St
03
= Open
04
= Pause
05
= "FAIL SAFE" tripped (chpt. 5.2)
06
= Now closing
07
= Now reversing
08
= Photocells tripped
5.2. ADVANCED PROGRAMMING
To access ADVANCED PROGRAMMING, press key F and, as you hold it
down, press key +:
•
if you release key + , the display indicates the name of the first function.
•
if you release key F too, the display shows the value of the function that
can be modified with keys + and -.
•
if you press key F (and hold it down), the display shows the name of the
next function, and if you release it, the value that can be modified with
keys + and - is shown.
•
when you reach the last function, press F to exit the program, and the
display resumes showing the gate status.
The following table shows the sequence of functions accessible in ADVAN-
CED PROGRAMMING:
ADVANCED PROGRAMMING
Display
Function
MAXIMUM TORQUE AT INITIAL THRUST:
The motor operate at maximum torque (ignoring
the torque setting) at start of movement. Useful
b0
for heavy leaves.
Y
= Active
no
= Disabled
F
Default
EP
C
opening /
closing)
0
59
to
sec. in one-
2.0
2.5
, pause time is 2 min.
50
-3
+
F +
Default
ADVANCED PROGRAMMING
Display
FINAL BRAKING:
When the gate engages the opening or closing
limit-switch, a braking stroke can be selected
to ensure the leaf is stopped immediately. If
decelerations are selected, braking starts when
they finish.
br
00
At
value, braking is disabled.
Time can be adjusted from
second steps.
E.g. if the display indicates
second.
00
= Braking disabled
01
from
to
FAIL SAFE:
If this function is activated, it enables a function
test of the photocells before any gate movement.
FS
If the test fails (photocells not serviceable signal-
led by value
not start moving.
Y
= Active
no
= Disabled
PRE-FLASHING (5 s):
Activates the flashing lamp for 5 seconds before
start of movement.
PF
no
= Disabled
oP
= Only before opening
CL
= Only before closing
OC
= Before every movement
INDICATOR-LIGHT:
00
If
is selected, the output functions as a stan-
dard indicator-light (lighted at opening and
pause, flashing at closing, and off when gate
closed).
Courtesy light: Different figures correspond to ti-
med activation of the output, which can be used
(by a relay) to power a courtesy lamp. Time can
be adjusted from
and from
Electric lock command and 'traffic lights' fun-
ctions:
If you press key
command for the
activated;
If you press
closing and opening electric lock is set;
if you press the
SP
'traffic lights' functions
00
= Standard indicator-light
01
from
to
E1
= electric lock command before opening
movement
E2
= electric lock command before opening and
closing movements
E3
= 'traffic lights' function: the output is active
in "open" and "open on pause" status and is
disabled 3 seconds before the closing manoe-
uvre starts.
there is 3 seconds of pre-flashing before the
closing manoeuvre.
E4
= 'traffic lights' function: the output is active
only in "closed" status.
Do not exceed the output's maximum load
(24Vdc-3W). If necessar y, use a relay
and a power supply source outside the
equipment.
CLOSING PHOTOCELLS LOGIC:
Select the tripping mode of the closing photo-
cells.
They operate for the closing movement only: they
Ph
stop movement and reverse it when they are
released, or they reverse it immediately.
Y
= Reverse on release
no
= Reverse immediately when opening
OPENING PHOTOCELLS LOGIC:
Select the tripping mode of the opening pho-
tocells.
They operate for the opening movement only:
oP
they stop the movement and restart it when they
Y
are released, or they reverse it immediately.
Y
= Reverse immediately when closing
no
= Restart movement on release
16
+
F +
Function
01
20
to
sec. in 0.1-
10
, braking time is 1
20
= Timed braking
05
on the display), the gate does
0
59
to
sec. in 1-second steps,
1.0
4.1
to
min. in 10-second steps.
-
00
from the
setting, the
E1
closing electric lock is
-
again, the command for the
-
key again, you can set the
E3
E4
and
.
4.1
= Timed output.
Default
05
no
no
E2
00
no
no