Servicing,
Specifications
6 Measurement points
The measurement points of the
functional units which are located
parallel to the terminals are acces
sible when mounted. For measure
ments, the test shaft cover must be
removed. After measuring, replace
the test shaft cover.
Exchanging the functional unit
Modules may only be exchanged by
specialist personnel when the equip
ment is not live, i.e. when discon
nected from the mains.
7 Release the operating panel using
the enclosed mounting key and take
it off.
8 Unscrew the FPM at the
mounting plate, tilt forward at the
top, remove from the mounting
plate and release the connecting
plug.
9 If necessary, set the operating
mode at the new FPM.
(see "Setting the operating
mode")
10 Connect the new FPM, insert and
screw to the mounting plate.
11 Carry out a function check
12 Place the operating panel on the
mounting panel and lock using the
mounting key.
The marking in the mounting key
must be flush when locked with the
upper edge of the operating panel.
Specifications
Operating voltage: 12 V AC
Operating current: max. 250 mA
Contact type: n.o. contact 24 V, 2 A
Switching time: 3 sec
Protection system: IP 54
Ambient temperature:
–20 °C to +55 °C
12
LED displays
Green LED
Red LED
Green LED and red LED flash alter
nately
–
Lights up
Lights up
–
–
–
Green LED flashes
–
for 3 seconds,
then green LED
lights continu
ously
Red LED flashes for 3 seconds,
then green LED lights continuously
Green LED and red LED flash simul
taneously
–
Rapid flashing
Meaning
power has been connected
or
the device has been initialized.
Module is ready for fingerprint
readin.
Operating mode
Fingerprint recognition is being
processed
Fingerprint has been recognized.
Fingerprint has not been recog
nized.
Delete mode can be activated for all
user fingers/module is reset to its as
delivered status
FPM is blocked as an unauthorized
fingerprint has been read in sev
eral times in succession. The block
can be lifted (operating status) by
reading in an authorized fingerprint
twice. The block is automatically
lifted after 1 minute, whereby the
blocked period increases with a
rising number of unauthorized
access attempts.