7.
MOUNTING THE INSTALLATION PLATE AND MAKING THE PIPING
FEEDTHROUGH.
7.1 Mounting the installation plate of the interior unit.
WARNING!
Use a pipe detector to detect electrical conduits and pipes in the wall before drilling the required
holes to prevent unnecessary damage to the wall or dangerous situations.
a.
F it the installation plate horizontally on structural parts of the wall with spaces around the instal-
lation plate. See figure 8.
b.
I f the wall is made of brick, concrete or the like, drill eight (8) 5mm diameter holes in the wall. Insert
clip anchor for appropriate mounting screws .
c.
Fit the installation plate on the wall with eight (8) type "A" screws .
G
REMARK
Mount the mounting plate and drill the holes in the wall corresponding to the material of the
wall and the mounting points on the mounting plate in question (dimensions are in "mm" unless
otherwise indicated).
Correct orientation
of Installation Plate
Figure 8
S(C)5x25/SC4125
Indoor unit outline
318mm
pipe hole
65mm
102mm
717mm
4
52
52
409mm
249mm
pipe hole
65mm
153mm
S(C)5x32/SC4132
Indoor unit outline
406.4mm
pipe hole
65mm
102mm
805mm
S(C)5x48/SC4148
Indoor unit outline
406.4mm
pipe hole
65mm
102mm
805mm
7.2
Drilling the piping, condensation hose and cable feed-through.
a.
D etermine the positions of the holes according to the diagram detailed in Fig. 9. Drill one (1) hole
(≥ 85 mm for SC41xx & SC5xxx / ≥ 65 mm for S41xx & S5xxx) slanting slightly downwards to outdoor
side, this will prevent water to come indoors (fig 10).
b.
Always use wall hole conduit when drilling metal grid, metal plate or the like.
452.7mm
249mm
pipe hole
65mm
153mm
452.7mm
249mm
pipe hole
65mm
153mm
4
53
53