6.2.2
HEPA filter cassette
To replace the HEPA filter cassette, do the following.
Fig. 6.2
• De-energize the unit.
• Open the back door (C).
• Remove the pre filter cassette.
• Slightly lift and remove the HEPA filter cassette (D).
• Dispose of the used HEPA filter cassette in accordance with
state or local regulations.
• Put a new HEPA filter cassette in the unit. The side pins (A)
exactly fit in the slits (B).
• Put the pre filter cassette back in the unit. Make sure that
the arrow on the frame points downwards
• Close and lock the door.
A
Fig. 6.2 Replacement of the HEPA filter cassette
6.3
arm adjustment
If the extraction arm, or a part of it, does not stay in the
desired position, you must adjust the friction.
• Determine which joint needs more or less friction.
• Loosen the hose at that position to get access to the hinge.
• Pull the arm in a horizontal position.
• Adjust the friction; refer to Fig. V on page 25 for the
adjustment points.
7

TRoublESHooTiNg

If the unit does not function (correctly), consult the checklist
below to see if you can remedy the error yourself. Should this
not be possible, contact your supplier.
WaRNiNg
Obey the safety regulations that are written in
chapter 3 when you carry out the activities below.
5. The arrow indicates the airflow direction. An incorrectly placed pre filter
cassette affects the filter lifetime.
0000115336/010518/0 MobileGo
.
5
60Hz
plus
Symptom
problem
The fan does
The unit does
not start
not function
B
The green
The unit does
C
LED is on but
not function
the fan does
not run
D
Poor
The unit does
extraction
not function
capacity
properly
The service
Poor
indicator (red
extraction
LED) is on
capacity
The
Escape of
extraction
fume; no
arm does not
proper
stay in the
extraction
desired
position
You cannot
get the arm
in the desired
position
8

ElEcTRical diagRaM

Refer to the separately supplied electrical diagram.
possible
Solution
cause
No mains
Connect the mains
voltage
voltage
Thermal
- Examine the fan
overload
and motor to find
protection is
the cause and
activated
remedy the
problem
- Push the red
button behind the
front panel to
reset. Refer to
Fig. IV on page
24.
The mains cord
Repair or replace
is defective
the mains cord
Loose contacts
Repair the contacts
Motor defective
Repair or replace
the motor
Relay is
Replace the relay
defective
Thermal relay is
Replace the thermal
defective
relay
Motor defective
Repair or replace
the motor
The shut-off
(Fully) open the
damper in the
shut-off damper
hood of the
extraction arm
is (partly)
closed
Clogged filters
Repair the
& loose
connection of the
connection of
pressure tubes
pressure sensor
Clogged filters
Replace the
& defective
pressure sensor &
pressure sensor
the pre filter
cassette
Replace the HEPA
filter cassette as
well
The pre filter is
Replace the pre
clogged
filter cassette
The HEPA filter
Replace the HEPA
is clogged
filter cassette
Friction setting
Adjust the friction;
is not correct
refer to Fig. V on
page 25 for the
adjustment points
EN - 8