Maintenance
Cannot receive more than a trickle of water:
Both hot and cold supply lines must be pressurized.
If only one side is pressurized, the system will not
allow adequate flow of water.
Faucet leaks from showerhead: Remove the
showerhead then turn the water on and off to verify
if the cartridge is leaking or the showerhead is
draining slowly (the showerhead may need to be
cleaned if water drains slowly).
If leak persists - SHUT OFF WATER SUPPLIES
Replace cartridge assembly - RP47201.
Unable to set or maintain mixed water temperature:
SHUT OFF WATER SUPPLIES. Remove handle
assembly, trim sleeve, and bonnet nut. Check
to make sure the "H" marking on the cartridge
aligns with the hot inlet and the "C" marking on the
cartridge aligns with the cold inlet to the valve body
The thermostatic cartridge cannot function if hot
and cold inlets are reversed.
Cartridge Summary Reference Sheet
17T
Brass
Order RP47201 to
Replace Cartridge.
Low flow: Low flow may be caused by clogged
screens within the thermostatic cartridge.
To clean the hot and cold screens in the cartridge,
follow the steps below:
1. SHUT OFF WATER SUPPLIES.
2. Remove the handle assembly.
3. Unscrew the hex shaped portion of the
cartridge.
4. Carefully clean any debris from the screens
under running water. If the debris is difficult to
remove then soak the screens overnight in a
50% water and 50% vinegar solution.
5. Reassemble the cartridge.
6. Replace the handle.
7 Turn the water back on.
8. Reset the limit stop before using the valve.