Kohler K-302 Guía De Instalación Y Cuidado página 6

Ocultar thumbs Ver también para K-302:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Shower Only Installations
NOTE: Shower only installations require two-valve yokes.
NOTE: Typical dimensions for bath and shower installations are
shown on the rough-in diagram.
NOTE: Refer to the trim installation instructions for specific
requirements.
NOTE: Refer to the handle installation instructions for possible
rough-in depth requirements.
Unless otherwise instructed, rough-in the supply yoke 2-1/4" (57
mm) minimum to 3" (76 mm) maximum from the centerline of
the yoke to the outside of the finished wall.
Install 1/2" hot and cold supply tubing.
If specified, install the screwdriver stop valves.
Using a 3/8" hex wrench, remove the aspirator from the yoke and
discard.
Install a plug in the spout pipe opening.
1205552-2-A
72"
(1829 mm)
To Floor
24"
(610 mm)
Plug
6
Kohler Co.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-303K-6934

Tabla de contenido