Mobile Magnum; Hose Assembly Setup - ICP HANDI-FOAM Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MOBILE MAGNUM

®
Nitrogen Bottle
Red Nitrogen Hose
2
with Coupling (A)
11
Shipping Packet
(attached to the
side of the A
Cylinder)
6
A-Side On/Off
Valve, Cylinder to
Hose Filter with
Temperature
Gauge Assembly
Prior to proceeding with setup, please review all instruction manuals, hose tag instructions and labels.
1. Verify chemical temperature is between 70–85°F (21–29°C), see TDS for product specific process (core)
chemical temperature recommendations.
2. Before/during the system start-up process update the Daily Spray Log (A18013).
3. Attach the Nitrogen Regulator (#1) to the nitrogen bottle. Tighten fitting with a wrench.
4. Attach the
A-Side Red
Tighten fitting with a wrench.
5. Attach the Quick Disconnect on the
6. Attach the B-Side Nitrogen Hose with Coupling (#3) to the B-Side Cylinder Nitrogen Regulator (#1).
Tighten fitting with a wrench.
7.
Attach the Quick Disconnect on the B-Side Nitrogen Hose with Coupling (#3) to the Nitrogen On/Off Valve
(#4).
8. Attach the Gun Hose Assembly (#9 or #14)
Tighten fitting with a wrench.
9. Attach the Gun Hose Assembly (#9 or #14) B-Side striped hose to the Magnum Hose (#10). Tighten fitting with
a wrench.
10. Ensure the Handi-Gun
engaged when trigger is released.
11. Remove the Cap (A cylinder) and Plug (B cylinder) from the Cylinder Outlet On/Off Valve (#5).
12. Attach the A-Side On/Off Valve, Cylinder to Hose Filter with Temperature Gauge Assembly (#6) to the
Cylinder Outlet On/Off Valve (#5) on the A-Side Cylinder. Tighten fitting with a wrench.
13. Attach the B-Side On/Off Valve, Cylinder to Hose Filter with Temperature Gauge Assembly (#7) to the
Cylinder Outlet On/Off Valve (#5) B-Side Cylinder. Tighten fitting with a wrench.
14. Open Ball Valves #5, #6, #7 and #8.
15. Plug the Heated Hose into a 120V grounded receptacle.
NOTE: Use of petroleum jelly (provided in nozzle packs) on all fittings will help prevent moisture
contamination on any exposed surfaces.
Storage Temperature
Optimum 75–85°F (24–29°C)
but not < 60°F or > 90°F
(not <16°C or >32°C)
6
REFILL SYSTEM 8 WITH A MAGNUM HEATED SYSTEM
Nitrogen Regulator
1
4
Nitrogen
On/Off Valve
Cylinder Outlet
A
B
On/Off Valve
5
10
13
Magnum Heated
System
®
Hose Assembly
Nitrogen Hose with Coupling (#2) to the A-Side Cylinder Nitrogen Regulator (#1).
A-Side Red
A-Side Red
Trigger Safety is engaged. The Handi-Gun II
®
Process (Core)
Chemical Temperature
70–85°F (21–29°C)
• Operating Instructions, Daily Spray Log & Bill of Lading are located in
the Shipping Packet on the side of the A-side cylinder.
• The Magnum Heated System
Magnum Heated hose.
Nitrogen Hose
3
with Coupling (B)
Hose to Gun
8
On/Off Valve
Assembly
7
B-Side On/Off
Valve, Cylinder to
Hose Filter with
Temperature
Gauge Assembly
Mobile Magnum
Cart
®
Nitrogen Hose (#2) to the Nitrogen On/Off Valve (#4).
striped hose to the
TM
Outside Application
Temperature
40—100°F (4–38°C)
SETUP
®
Hose Care Instruction is attached to the
®
10" (25 cm)
Handi-Gun
ColorWise
Nozzle
®
Hose Assembly
(Cone or Fan)
12
Handi-Gun
®
Trigger Safety
ColorWise
®
OR
15
(Long Cone or Fan)
Hi
Lo
14
Handi-Gun II
Hose Assembly
Handi-Gun II
TM
Trigger Safety
A-Side Red
Magnum Hose (#10).
(#14) Trigger Safety is automatically
Surface Temperature
40—100°F (4–38°C)
®
9
Nozzle
TM

Publicidad

Tabla de contenido
loading