• This steam machine is equipped with several feedback mechanisms that alert the operator when an unusual condition occurs.
Description
Module not heating
Note on safety reset switches
Tap not dispensing
Steam and/or water is visible around the ball fitting
22
Troubleshooting
Verify that the power switch is turned clockwise to the operating mode position and
not counterclockwise to the standby mode position.
The steam module features two safety reset thermostat controlled switches,
attached near the heater port on the boiler. If the steam boiler does not heat it may
be due to the activation of the safety reset switches, which are triggered by excess
temperature and signify abnormal operation and possibly failed components. The
safety switches mentioned are internal to the steam module and are not user
resettable.If you believe a safety switch has been activated, the module may require
service by anauthorized technician. Please contact Modbar for additional support
and information.
Verify that there is water in the sight glass. If the boiler is over or under full, this
will cause the tap to cease functioning.
Verify that pressure is adequate. If the temperature is programmed to below boiling,
the tap will not function.
This indicates that the o-ring is beginning to wear, and that the machine will soon
need preventative maintenance. Please contact Modbar Support for an o-ring kit,
as well as detailed replacement instructions.
Message Solution