PUSHDIM
Dip-switches related to rolling speed (S4-9 and S4-10) are meaningless under this mode.
To set SWITCH-ON mode (see also below 10.3): locate S5 dip-switch and set as per Table 8.
SWITCH-ON mode
Safety: system remains switched-off after a loss and return of the electric net
Wall switch: system restore last stored scenery after a loss and return of the electric net
Table 8: Settings of dip-switches S5 in PUSHDIM mode to choose SWITCH-ON mode after a loss and return of electric net.
NB: please note that the meaning of these modes is:
-
Safety: to let the system remain safely switched off after a loss and return of electric net.
-
Wall switch: to be able to switch on and off the system by means a wall-switch or timer-switch. Last stored scenery will be
restored when wall switch or timer-switch is re-activated.
25
S4-8
S4-7
S4-6
Indirect
Indirect
Indirect
Monochr.
Blue
Green
OFF
OFF
OFF
Table 7: Settings of dip-switches S4 for activating PUSHDIM mode
Fig. 10: Settings of dip-switches for activating PUSHDIM mode
DIP-switches S4
S4-5
S4-4
S4-3
Indirect
Direct
Direct
Red
Monochr.
Blue
OFF
OFF
OFF
S4-2
S4-1
Direct
Direct
Green
Red
OFF
OFF
DIP-switches S5
S5-1
S5-2
OFF
OFF
ON
OFF