Operations :
• Manual remote control (GYS product ref. 045675).
The manual remote control can adjust :
- the current from 50% to 100% of the set intensity using the main knob. The displayed current setpoint matches the potentiometer position. The
displayed current setpoint becomes a 100% of the settings when the main knob is turned towards the machine's keypad.
- from minimum to the maximum of the voltage range (then the main knob has no effect). The voltage display shows the remote control variation.
• Foot pedal (option ref. 045682) :
The pedal control can adjust :
- the current from 50% to 100% of the set intensity using the main knob. The displayed current setpoint corresponds to a 100% of the value.
Connectors
Beyond the manual remote control and the pedal, it is possible to create you own connectors using the optional male socket (ref. 045699). For the
cabling layout, please see the diagram below utiliser a 10 kΩ potentiometer).
ref. 045699
COOLING FAN
To minimise sound and dust aspiration, the station integrates a controlled fan system. The fan's rotation speed depends on the temperature and the
machine's settings.
LOCKING CONTROLS
That feature can lock the knobs and keypad to prevent accidental changes in the settings.
Operation :
Press the button
for 3 seconds, the display shows
No button is enabled, the secondary knob is disabled, the main knob can adjust the value at +/- of the percentage, defined by the «tolerance» setting
(see chapter «Access to menus»).
To unlock the commands, press the
n°11) switches off.
ACCESS TO MENUS
Welding MMI
output
22
EXAGON 400 CC/CV
G
F
A
B
E
D
C
External view
Electric diagram according to the remote control type.
and goes back to current display. The LED (FIG-2, n°11) switches on.
button for 3 seconds, the display shows
+
x 3s
+
Buttons' release
Current process
settings menu
Exit settings menu
Current
value
D
C
B
A
then goes back to current display. The LED (FIG-2,
...
...
Only for MMA and Vertical up
MMA
...
1s
1s
EN
Load settings
and menu exit
Save settings and
menu exit
Validate tolerance
settings and back
to root menu
1s
Reset all settings
for all processes