Downloading Of Stored Measurement Results; Compacsoft[Plus] Software Installation; 25 5.14 Fsa 050 Settings - Bosch FSA 050 Manual Original

Ocultar thumbs Ver también para FSA 050:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 89
5.11.2
Deletion of all stored measurement results
1. Set the rotary switch to <DEL> (fig. 2, pos. 5).
 The measurement result last stored is displayed.
i
If no results have been stored so far, three dashes
appear on the display.
2. Press the function key  (fig. 3, pos. 4).
appears on the LCD.
ALL
3. Press <
/OK> to delete all measurement results.
 All the results stored are deleted.
 After deletion, three dashes appear on the LCD.
5.12
Downloading of stored measurement
results
To load the stored measurement results from
the FSA 050 via Bluetooth onto a computer, the
CompacSoft[plus] software must be installed on
the computer. Information on this function can be
found in the CompacSoft[plus] software Online Help.
Communication via Bluetooth is only possible with the
FSA 050 set to "FSA" status and the rotary switch in
<SND> position.
SET UP – Setting status
1. Set the rotary switch to <SETUP> (fig. 2, pos. 6).
 The firmware version of the FSA 050 is displayed
for four seconds and then
 The status of the FSA 050 (FSA or STA).
2. Press <TEST> (fig. 2, pos. 1) for approx. two
seconds.
 The status of the FSA 050 changes.
 The buzzer sounds briefly.
 The lock symbol
on the LCD flashes.
3. Briefly pressing <TEST> changes the status (FSA or
STA) of the FSA 050.
4. Press <
/OK> to store the status "FSA"
(fig. 2, pos. 2).
The desired value has been stored when the lock
symbol
disappears from the LCD.
5.13
CompacSoft[plus] software
installation
1. End all open applications.
2. Insert the "CompacSoft[plus]" DVD in the DVD drive.
3. Start "Windows Explorer".
4. START 'D:\RBSETUP.EXE' n (D = DVD drive letter).
 Set-up is started.
5. Heed and follow the instructions on the screen.
6. Re-start the computer to complete the installation.
 This completes CompacSoft[plus] installation.
 DSA is started.
Robert Bosch GmbH
Operation | FSA 050 | 33
5.14
FSA 050 Settings
1. In the DSA, select "FSA 050/720/740/750/760" or
"FSA 050/500".
 FSA 050/720/740/750/760 or FSA 050/500 is
started.
 The "Settings" window opens.
i
The "Settings" window is only opened automatically
the first time the FSA software is started.
2. In the FSA 050 field, select the Use option.
i
In the FSA measuring module field, only select the
Use option if FSA 500/720/740/750/760 is available.
3. Press <F7>.
 The "FSA 050 Settings" window is displayed.
4. Enter the MAC address (the FSA 050 MAC address is
printed under the protective rubber on the reverse
side of the device).
5. Press <F12>.
 Bluetooth driver is installed.
i
If no Bluetooth driver is already installed on the
computer, driver installation starts automatically.
Only the Bluetooth USB adapter supplied is to be
used for the Bluetooth connection with FSA 050.
Do not plug the Bluetooth USB adapter into the
computer until requested to do so during driver
installation. Heed and follow the instructions on the
screen during Bluetooth driver installation.
6. Re-start the computer to complete the installation.
 DSA is started.
7. Select "FSA 050/720/740/750/760" or "FSA 050/500".
 FSA 050/720/740/750/760 or FSA 050/500 is
started.
i
In order to be able select FSA 050 test steps in the
FSA 050/720/740/750/760 or FSA 050/500 start
screen, an electric hybrid vehicle must be selected
in the vehicle identification.
"
The FSA 050 is ready to operate.
i
Operation of the FSA 050 with FSA 500/7xx
is described in the Online Help of the
CompacSoft[plus] software.
en
|
1 689 989 102
2019-05-24

Publicidad

Tabla de contenido
loading

Tabla de contenido