GAS REQUIREMENTS
{GAS MODELS ONLY)
CONNECTING
GAS DRYERS
WARNING:
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions,
including the following:
Use only natural or LP (liquid propane) gases.
THE INSTALLATION
MUST CONFORM WITH LOCAL
CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH
THE NATIONAL FUEL GAS CODE ANSI/Z223.1,
LATEST
REVISION (FOR THE UNITED STATES), OR WITH THE
CAN/CGA-B149
INSTALLATION CODES (FOR CANADA).
Gas dryers are equipped with a burner vent for use with natural
gas. If you plan to use your dryer with LP (liquid propane) gas,
it must be converted for safe and proper performance by a
qualified service technician.
A 1/Z' (1.27 cm) gas supply line is recommended and must be
reduced to connect to the 3/8" (1 cm) gas line on your dryer. The
National Fuel Gas Code requires that an accessible, approved
manual gas shut-off valve be installed within 6' of your dryer.
Gas dryers installed in residential
garages
must be raised
18 inches (46 era) above the floor.
Additionally, a 1/8" (0.3 cm) N.P.T. (National Pipe Thread) plugged
tapping, accessible for test gauge connection, must be installed
immediately upstream of your dryer's gas supply connection.
Your Dryer must be disconnected from the gas supply pipe
system during any pressure testing of the system.
DO NOT reuse old flexible metal gas lines. Flexible gas lines
must be design certified by the American Gas Association (CGA
in Canada).
NOTE:
,, Any pipe joint compound used must be resistant to the action
of any liquefied petroleum gas.
,, As a courtesy, most local gas utilities will inspect a gas
appliance installation.
GAS IGNITION - Your Dryer uses an automatic ignition system
to ignite the burner. There is no constant burning pilot.
Commonwealth
of massachusetts
installation
instructions
Your Dryer must be installed by a licensed plumber or gas fitter. A
"T" handle manual gas valve must be installed in the gas supply
line to your dryer. If a flexible gas connector is used to install your
Dryer, the connector must have a maximum length of 3' (36").
WARNING:
,, Gas leaks may occur in your system, creating a dangerous
situation.
,, Gas leaks may not be detected by smell alone.
,, Gas suppliers recommend you purchase and install a UL-
approved gas detector.
Install and use in accordance with manufacturer's instructions.
Electrical
requirements
for gas models only
Do not, under any circumstances,
cut or remove the
third (ground) prong from the power cord. Failure to follow
this warning can result in fire, explosion, or death.
For personal safety, this dryer must be properly
grounded.
Failure to follow this warning can result in fire,
explosion, or death.
The power cord of this dryer is equipped with a 3-prong
(grounding)
plug which mates with a standard
3-prong
(grounding)
wall outlet to minimize
the possibility of
electric
shock hazard from this appliance.
Failure to
follow this warning can result in fire, explosion, or death.
A 120 volt, 60 Hz AC approved electrical service, with a 15-
amp fuse or circuit breaker is required.
Where a standard
2-prong
wall outlet
is encountered,
it
is your personal responsibility
and obligation
to have it
replaced
with a properly grounded
3-prong wall outlet.
Failure to follow this warning can result in fire, explosion, or
death.
..............................
3-prong grounding type
wall receptacle
Ensureproper ground
exists before use.
_
10
KenmoreDi?erOwnersManual-01
EN.indd
10
2010-06-17
q73:33:44