Front part maintenance
GB
Electrovalve
substitution/maintenance
Using a 12 mm. spanner unscrew the teflon tube,
while holding the locknut with another similar
spanner, which connects the pump to the
electrovalve.
Remove the tube from the electrovalve.
Unscrew and remove the fixing screw from the
multipolar connector.
Unscrew the locknut from the electrovalve, using a
14 mm. socket.
Remove the electrovalve.
35