EGC-FA
Size
Screw (side/top)
Max. screw-in depth D
Centring (H7)
Tightening torque
Tab. 3
For hard and stiff payloads (steel):
Note
A warped attachment component bends the slide
and shortens the service life of the guide.
Use an attachment component with an even sur
face.
Evenness: t = 0.01 mm.
5.1.3
Mounting the accessories
To protect the end positions against uncontrolled excess travel:
Check the necessity of proximity sensors (hardware limit switches).
If proximity sensors are used as limit switches:
Preferably use proximity sensors with normally-closed function.
This protects against excess travel beyond the end position, if the proximity sensor cable is broken.
If proximity switches are used as reference switches:
Use proximity sensors that correspond to the input of the controller being used.
Use proximity sensors with switch lug aB (è Assembly instructions for the accessory).
Mounting
in the slots 7 (è Fig. 1)
Tab. 4
Avoid external influences from magnetic or ferritic parts in the vicinity of the proximity sensors (min
imum distance of 10 mm from the slot nuts).
Protect the end positions. Attach emergency buffers or shock absorbers to the shock absorber re
tainer.
Avoid contamination. Use slot covers in all unused slots.
20
70
M5
[mm]
8.4
5
[mm]
[Nm]
5.9
aB
7
80
120
M5/M6
9.5
10
7/9
5.9/9.9
Fig. 6
With mounting bracket aA
Festo – EGC-FA – 1507a English
185
M6/M8
15
9
9.9/24
t
aA
aB