Mounting The Accessories - Festo EGC-FA Instrucciones De Utilizacion

Ocultar thumbs Ver también para EGC-FA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EGC-FA
Size
Screw (side/top)
Max. screw-in depth D
Centring (H7)
Tightening torque
Tab. 3
For hard and stiff payloads (steel):
Note
A warped attachment component bends the slide
and shortens the service life of the guide.
• Use an attachment component with an even sur­
face.
Evenness: t = 0.01 mm.
5.1.3

Mounting the accessories

To protect the end positions against uncontrolled excess travel:
• Check the necessity of proximity sensors (hardware limit switches).
If proximity sensors are used as limit switches:
• Preferably use proximity sensors with normally-closed function.
This protects against excess travel beyond the end position, if the proximity sensor cable is broken.
If proximity switches are used as reference switches:
• Use proximity sensors that correspond to the input of the controller being used.
• Use proximity sensors with switch lug aB (è Assembly instructions for the accessory).
Mounting
in the slots 7 (è Fig. 1)
Tab. 4
• Avoid external influences from magnetic or ferritic parts in the vicinity of the proximity sensors (min­
imum distance of 10 mm from the slot nuts).
• Protect the end positions. Attach emergency buffers or shock absorbers to the shock absorber re­
tainer.
• Avoid contamination. Use slot covers in all unused slots.
20
70
M5
[mm]
8.4
5
[mm]
[Nm]
5.9
aB
7
80
120
M5/M6
9.5
10
7/9
5.9/9.9
Fig. 6
With mounting bracket aA
Festo – EGC-FA – 1507a English
185
M6/M8
15
9
9.9/24
t
aA
aB

Publicidad