6.2 BATTERY CHARGER CONFIGURATION
We recommend to call the assistance centre or a
technician if you have problems with the setting
given.The machine is equipped with a battery
charger configurated for GEL maintenance
free battery.
If you whish to equip the machine with Pb-Acid bat-
teries, AGM or OPTIMA batteries, it is necessary to
change the battery charger settings as follows:
!
(
) DISPLAY OF THE BATTERY CHARGER SET-
TINGS
The battery charger settings are shown by the
blinking of the LED indicator when the battery
charger is switching on:
- the RED LED indicator ( Photo 13 -B )
flashes 2 times = the battery charger is set for
PB-Acid batteries
- the GREEN LED indicator ( Photo 13 - C )
flashes 2 times = the battery charger is set for
B
A
Photo 13
Table A
Battery type
Pb-Acid
GEL
(default)
Exide-Sonnenshein-Haze
AGM
Discover
AGM
Optima
6 - INSTALLATION INFORMATIONS
D
E
F
SW1
Dip-Switch 1 Dip-Switch 2
ON
OFF
OFF
OFF
OFF
ON
ON
ON
GEL/AGM or OPTIMA batteries.
The battery charger settings will be displayed even
if the battery is not connected.
!
(
) DIP-SWITCH CONFIGURATION FOR CHARG-
ING CURVE SETTINGS FOR BATTERY CHARGER
CBHD1-XR 24V 12A
To set the charging curve type for Pb-Acid,
GEL/AGM or OPTIMA batteries it is necessary to
operate on the dip-switches placed inside the
battery charger ( Photo 13 - D ) ( Photo 13 - F ).
To access the dip-switches it is necessary to remove
the lower panel of the battery charger ( Photo 13 -
A ); it is also possible to reach the dip-switches by
removing the plastic cap ( Photo 13 - E ).
To configurate the charging curve related to the dif-
ferent battery type it is necessary to set the dip-
switches as indicated in the Table A here below:
A) Battery charger cover
B) Red "LED" - Battery discharged
C
C) Green "LED" - Battery charged
D) Dip-Switches
E) Plastic cap
F) Dip-Switches for charging curve set-
ting
SW1
34
SW 1
ON
ON
OFF
OFF
OFF
DIP 1
DIP 2