The box is now
adjusted.
Push button to
continue.
Press the PTK again to access the next screen:
Set the time between
changing the power
level of the box.
4s
Turn until the desired interval is reached (up to 250
seconds).
For small spaces we recommend to select a short
interval (5-10 seconds), and for large spaces a somewhat
longer interval.
If the temperature keeps fluctuating with the current
settings, you can change the interval.
If the temperature often increases too high, it is
recommended to shorten the interval. If the temperature
often falls too low, it is recommended to increase the
interval.
Confirm by pressing the PTK.
You access the main screen.
TMP = 33.6 °C
RH =
66%
BOX =
90%
CO2 = 1112 PPM
9.2 Standard menu
If you are not using the Custom menu (section 9.1),
select "Standard" and confirm by pressing the PTK.
Select box
Custom
=> Standard
Select the type of fan (m
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
) by turning the PTK.
3
Select fan
2500 m3
Push to confirm
By pressing the PTK, this fan is set as default. When
rebooting the Clima Control Plus, these fan settings will
be used.
You access the next screen:
Set the time between
changing the power
level of the box.
4s
Turn the PTK until the desired interval is reached (up to
250 seconds).
For small spaces we recommend to select a short
interval (5-10 seconds), and for large spaces a somewhat
longer interval.
If the temperature keeps fluctuating with the current
settings, you can change the interval.
If the temperature often increases too high, it is
recommended to shorten the interval. If the temperature
often falls too low, it is recommended to increase the
interval.
Confirm by pressing the PTK.
You access the main screen.
9.3 Automatic or manual operation
You are in the main screen. Select "BOX" and press the
PTK.
TMP = 33.6 °C
RH =
66%
=> BOX =
90%
CO2 = 1112 PPM
Select "BOX A/M".
21