Set Hysteresis; Set Temperature Alarm; Set Temp Offset - TechGrow Clima Control Plus Manual Del Usario

Ocultar thumbs Ver también para Clima Control Plus:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
=> TMP = 33.6 °C
RH =
66%
BOX =
90%
CO2 = 1112 PPM
Press the PTK.
=> Temp day
28.0°
Temp night 28.0°
Temp +/-
2.0°
>> NEXT >>
Select "Temp day", press the PTK and set the desired day
temperature by turning the PTK.
Press the PTK to confirm.
Temp day
28.0°
=> Temp night 28.0°
Temp +/-
2.0°
>> NEXT >>
Select "Temp night" and press the PTK. Turn the PTK to
set the desired night temperature.
Press the PTK to confirm.

10.1 Set hysteresis

You are in the main screen.
Press the PTK once and select "TMP".
=> TMP = 30.6 °C
RH =
66%
BOX =
90%
CO2 = 1112 PPM
Press the PTK.
Temp day
28.0°
Temp night 28.0°
=> Temp +/-
2.0°
>> NEXT >>
Select "Temp +/-" and press the PTK. Turn the PTK to set
the desired hysteresis.
Press the PTK to confirm.
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions

10.2 Set temperature alarm

You are in the main screen. Press the PTK once and
select "TMP".
=> TMP = 33.6 °C
RH =
66%
BOX =
90%
CO2 = 1112 PPM
Press the PTK and select >> NEXT >>.
Temp day
28.0°
Temp night 28.0°
Temp +/-
2.0°
=> >> NEXT >>
Press the PTK and select "Overtemp".
=> Overtemp 34.0°
Temp offset 0.0°
Night delay
5m
>> NEXT >>
Press the PTK and set the desired overtemp value.
Press the PTK to confirm.
If the daytime temperature exceeds the set limit, the
alarm contact is activated. For example, if the box breaks
down or does not have enough capacity to suck, this
function will intervene.

10.3 Set Temp offset

Although the temperature sensor is very accurate, it may
be desirable to align it with other measuring equipment.
"Temp offset" allows you to adjust the indication with
+ or - 5.0 °C.
Select "Temp offset" in the TMP menu and press the
PTK.
Overtemp 32.0°
=> Temp offset 0.0°
Night delay
5m
>> NEXT >>
23

Publicidad

Tabla de contenido
loading

Tabla de contenido