Installation
Shower
Dimensions
1
Rough-In Piping
Supply inlets are 1/2" NPT flexible hose and are accessible from the back of the shower or from knockouts on the top cover.
Bradley's Equa-Flo valve shown; other valve versions install in similar manner.
If supplies will be run "thru-wall", Bradley recommends using a 90° street ell to connect the supply hoses.
If supplies will be run "from above", Bradley recommends running them approximately 1/2" into the top cover.
2
Install Shower
Using the shower hinge as a
template, mark wall and drill
A
holes for 1/4" fasteners (wall
anchors and fasteners sup-
plied by installer). Secure
hinge side to the wall.
Bradley • 215-1441A Rev. D; ECN 12-03-014
Supplies from above
Hot
5-1/8"
(130)
Front
12"
(305)
29"
(737)
5"
(127)
Coming off
center of screw
48"(1219)
max. A.F.F.
6-3/4"
(173) 4"
(102)
Cold
or
Tempered
Rear
Supplies
Thru
Wall
4"
37-5/8"
(102)
(955)
3-1/8"
(79)
Connect the 1/2" flexible
B
hoses to the supply lines.
Turn the water on and
check for leaks and
adequate water spray.
Close the
shower tight to
the wall and
mark the holes
C
for the mounting
tabs on the wall.
mark wall and
drill holes for
1/4" fasteners.
Secure tabs to
the wall.
1"
(25)
3-1/2"
(89)
31-3/4"
(806)
15-3/8"
(397)
1-3/8"
(35)
1/2"
(12)
1/2"
6-3/4"
(12)
(173)
11/30/2012
WS-1XHN
32-5/8"
(828)
3-1/4"
(83)
3