Malfunction
Pumping does not produce pressure
Safety valve opens too soon, does not spray in
spite of pressure, or it only sprays with a poor
spray jet
Difficult pump movement when pumping / pump
is difficult to screw in and out
For other malfunctions, please consult a specialized workshop. We expressly state that the manufacturer is not
liable, according to the German Product Liability Law, for damages caused by this device, if such damages are
caused by unprofessional repair, or by the replacement of parts that are not original replacement parts specified
for this device, or parts have been used that are not approved by the manufacturer, and repair has not been
executed by the manufacturer or by an authorized dealer.
Specification
Hollow Cone Tip 1 mm
orifice grey
*)
Hollow Cone Jet 1,4 mm
orifice black
**)
Hollow Cone Jet 1,8mm
orifice blue
**)
No-Drift DT 1,0 yellow
**)
No-drift DT 1,0 red
**)
Adjustable nozzle brass
**)
Flat Spray Tip green
**)
Flat Spray Tip yellow
**)
Flat Spray Tip red *)
*) Standard equipment **) Accessories
ENGLISH 4
Remedy
- Screw the pump in more tightly
- Firmly fasten the threaded collar on the spray tube (shut-off
- Firmly fasten the safety valve.
- Unscrew it and apply Vaseline, reinstall. Firmly fasten the
- clean nozzle
- clean filter
Clean and lubricate O-ring on the pump plunger with
Vaseline, also possibly clean the interior of the cylinder and
lubricate with Vaseline (Fig. 8.4)
Lubricate the O-ring on the upper pump end with Vaseline
(Fig.8.3), lubricate threads
7. Specification of nozzle tips
Order-No.
Delivery
l/min
49 00 209
0.4
0.55
49 00 252
0.64
0.91
1.11
49 00 322
0.88
1.25
1.53
40 74 385
0.46
0.65
0.80
40 74 386
0.91
1.29
1.60
49 00 206
0.44 - 1.10
0.55 - 1.45
0.66 - 1.75
40 74 504
0.39
0.49
0.60
40 74 501
0.46
0.65
0.80
40 74 263
0.92
1.31
1.60
valve and container).
threaded collar, check the O-ring (Fig. 8.4) on the pump
plunger, check the pressure valve (Fig. 8.6) on the pump
plunger.
Pressure
Angle
bar
1.0
50° - 70°
2.0
1.0
50° - 70°
2.0
3.0
1.0
50° - 70°
2.0
3.0
1.0
105°
2.0
3.0
1.0
105°
2.0
3.0
1.0
2.0
3.0
1.0
80°
2.0
3.0
1.0
80°
2.0
3.0
1.0
110°
2.0
3.0
Applications
For treatment of shrubs, bushes
Mainly for herbicides at low
pressure