Switch on the power and make sure that the red indicator LEDS are in the following condition:
- L1
Power on LED
- L4
Safety LED for the closing travel limit leaf 1
- L5
Safety LED for the opening travel limit leaf 1
- L6
Safety LED for the closing travel limit leaf 2
- L7
Safety LED for the opening travel limit leaf 2
- L8
Signal LED opening button
- L9
Signal LED closing button
- L10 Safety LED for the blocking button
- L11 Safety LED for the inversion photo electric cells
- L12 Safety LED for the stop photo electric cells
*The LEDs are "ON" if the relative security device is inactive (depends on the position of the door and the
presence of the relative safety device).
Check that the activation of the safety devices switches off the corresponding LEDS.
If the power on LED "L1" doesn't light up check the condition of the fuse "F1" and the 230V~ power
cable connection.
If one or more of the safety LEDS do not light up check the contacts of the relative security devices and check that
the unused safety device contacts have been bridged.
INDICATIONS ON THE DISPLAY
alarm caused by both mechanical travel limits being activated together
memorised parameter error
time programming mode block ( caused by: TB, FTC_I, FTC_S )
defining the system configuration
waiting period after a programming stage
waiting period after deceleration programming
waiting period after electrical input sensor programming
deceleration time setting (value 1)
level 1 electrical input sensor
work time programming
opening cycle
block
automatic reclosing pause (only if enabled)
closing stage
updating the electrical input monitoring system leaf 1 (during programming)
17
on
"FCC1"
on*
"FCA1"
on*
on*
"FCC2"
"FCA2"
on*
"TA"
off
"TC"
off
"TB"
on*
"FTC_I"
on*
"FTC_S"
on*