INTEGRATED
ANTI-TIP
I N S TA L L C O N C R E T E W E D G E A N C H O R S
1)
A C C E S S O R I E S
2)
Optional acces-
sories are available
through your
Sub-Zero dealer. To
obtain local dealer
information, visit
3)
our website,
subzero.com.
14
I N S TA L L AT I O N I N S T R U C T I O N S
B L O C K I N G B R A C K E T
Drill a 10 mm diameter hole any depth
exceeding the minimum embedment. Clean
the hole or continue drilling additional
depth to accommodate drill fines. Use a
carbide drill bit.
Assemble the washer and nut flush with the
end of anchor to protect threads. Drive the
anchor through the material to be fastened
until the washer is flush with the surface
material.
Expand the anchor by tightening the nut
3–5 turns past hand-tight position or to 25
foot-pounds (34N) of torque.
Always wear safety glasses and use other
necessary protective devices or apparel
when installing or working with anchors.
Anchors are not recommended for use in
lightweight masonry material such as
block or brick, or for use in new concrete
which has not had sufficient time to cure.
The use of core drills is not recommended
to drill holes for the anchors.
POSITION
T H E U N I T
Before moving the Integrated unit into
position, secure the door closed and
remove the drawers.
IMPORTANT NOTE: On base units, the top
drawer has a control cable that needs to be
disconnected before removing this drawer.
Refer to illustration 3 below for placement and
how to disconnect this fitting.
The drawers should be placed aside until you
are ready for installation of the panels.
Remove the decorative top and side molding
pieces and the kickplate/grille.
IMPORTANT NOTE: If two Integrated units are
installed closer than 51 mm to one another, it
is necessary to use the Sub-Zero dual installa-
tion heater kit (ICBTTDUAL). Refer to Dual
Installations on page 21 for additional informa-
tion. The heater plate from this kit must be
attached to the left side exterior of the right
hand unit before the units are slid into
position.