Descargar Imprimir esta página

Sub-Zero ICB700TR Instrucciones De Instalación página 8

Ocultar thumbs Ver también para ICB700TR:

Publicidad

Idiomas disponibles

Idiomas disponibles

INTEGRATED
I N S TA L L AT I O N I N S T R U C T I O N S
ELECTRICAL
R E Q U I R E M E N T S
A 220-240 V AC, 50/60 Hz, 10 amp circuit
breaker and electrical supply are required. A
separate service, servicing only this appliance,
is required.
All Integrated models are equipped with a
power supply cord with a 3-prong grounding
plug, which must be plugged into a mating
3-prong ground ing-type wall recep tacle. Follow
all local codes and ordinances when installing
the receptacle. For location of the electrical
supply, refer to the Installation illustration for
your unit on pages 6–8.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and
may cause interruption of operation.
Do not use an extension cord or two-prong
adapter. Electrical ground is required on
this appliance. Do not remove the power
supply cord ground prong.
The outlet must be checked by a qualified
electrician to be sure that it is wired with
the correct polarity. Verify that the outlet
provides 220-240V AC and is properly
grounded.
Always shut power off at the circuit
breaker before performing any installa-
tion, service or maintenance.
IMPORTANT NOTE: The Integrated line is
equipped with an appliance inlet type device.
This allows easy replacement of the power
cord. The appliance inlet is located on top of
the unit on the compressor shroud. When
replacing the power cord make sure that the
replacement cord is rated HO5VV-F3G1.0 or
equivalent to ensure safe operation of the
appliance.
9

Publicidad

loading