IGNITION INSTRUCTIONS
REGULATOR, BURNER AND GAS VALVE
this unit, connect hose adapter to 20LB LP Gas Cylinder, turn gas cylinder valve ON, push adjustable regulator
in and turn counter-clockwise 1/4 turn to HIGH setting. Push ignitor button to light.
• From the LOCK OFF position, turn the regulator control knob counter-clockwise to the OFF position, push
regulator control knob down and turn counter-clockwise to HIGH position. Push ignitor button to light.
• If ignition does not take place within five seconds, turn the gas flow off by turning regulator control knob
clockwise to LOW position. Push down on regulator control knob and turn clockwise to OFF allowing the
regulator control knob to "pop up" as shown below. Wait five minutes and repeat lighting procedures. If ignition
still does not occur, see MATCH LIGHT INSTRUCTIONS.
• Always ensure that smoker door(s) are open before igniting. Gas can accumulate in smoker.
• If flame goes out during cooking, turn the gas flow off by turning regulator control knob clockwise to LOW
position. Push down on regulator control knob and turn clockwise to OFF allowing the regulator control knob to
"pop up", open door and wait 5 minutes then repeat ignition instructions.
• After use, turn adjustable regulator valve OFF and disconnect tank, if using a hose adapter turn adjustable
regulator OFF, then turn gas cylinder valve OFF and disconnect and remove the gas cylinder.
1. Read all instructions and warnings before lighting.
2. Check regulator control knob on regulator valve to be certain it is in LOCK OFF position before
connecting to gas cylinder.
3. Perform soapy water test before each use.
4. Open door before lighting, remove all accessories and cooking vessels from in/or on unit.
5. From the LOCK OFF position, turn the regulator control knob counter-clockwise to the OFF position,
push regulator control knob down and turn counter-clockwise to HIGH position.
6. Place a long lit match or candle lighter through lighting hole close enough to burner to ignite.
• Regulator control knob adjusts burner flame. Turn regulator control knob clockwise to
decrease flame. Turn regulator control knob counter-clockwise SLOWLY to increase flame. Turn
regulator control knob clockwise to LOW position. Push down on regulator control knob and turn
clockwise to OFF allowing the regulator control knob to "pop up" to shut flame off.
• Visually check burner flame. A CORRECT FLAME should be blue with a small amount of
yellow at the tip. An INCORRECT FLAME is excessively yellow and irregular. If an incorrect
flame occurs, turn regulator control knob clockwise to LOW
position. Push down on regulator control knob and turn clockwise
to OFF allowing the regulator control knob to "pop up". Allow unit
to cool and then clean burner. Let burner completely dry before
re-lighting.
7. If burner does not ignite after 5 seconds, turn the gas flow off by
turning regulator control knob clockwise to LOW position. Push down
on regulator control knob and turn clockwise to OFF allowing the
regulator control knob to "pop up". Wait five minutes and then re-try.
8. After use, turn regulator control knob clockwise to LOW position.
Push down on regulator control knob and turn clockwise to OFF
allowing the regulator control knob to "pop up" and continue turning
clockwise to LOCK OFF position to lock the regulator control knob in the up position. Disconnect and
remove the gas cylinder.