Volumetric regeneration (606 only)
A
Press
until desired capacity appears then release.
Range from 0.4 to 9.5 m
3
from 0.4 m
to 1.0 m
3
from 1.0 m
to 3.0 m
3
from 3.0 m
to 5.0 m
3
from 5.0 m
to 9.5 m
Calendar Override Setting (606 only)
The 606 controller needs a method to set days between regeneration for regulatory
requirements and in cases when the flow sensor has failed.
A
Press and hold
and
The programmed calendar override is displayed.
B
Press
to increases value.
Range from 0 through 30;
0 = Disabled;
0.3 = Regeneration every 8 hours : at 2, 10 and 18 hours;
0.5 = Regeneration every 12 hours : at 2 and 14 hours;
1 - 30 = Regeneration every X days (every 3 days in this example).
4.2.
History
A
To access the history values, press and hold simultaneously
B
Press
to navigate through the table. When the desired code is reached, press
5 .
Operation
5.1.
Recommendations
• Use only regenerate salts designed for water softening EN973;
• For optimal system operation, the use of clean salt free from impurities is recommended (for example salt pellets);
• Do not use ice melt, block, or rock salts;
• The sanitizing process (both with liquid and electrochlorination) introduces chlorine elements which may reduce the life of
the ion exchange resins. Refer to the technical guides for resins in common use, providing necessary checks on the system.
5.2.

Manual regeneration

Immediate regeneration
A
Press and hold
for 3 seconds to initiate an immediate
regeneration.
The controller displays a cascading symbol "--".
Note:
Press
to display the current cycle "C#"or the "--".
Quick cycle to service position
A
Press and hold simultaneously
The controller will skip the remaining regeneration cycles and return to the service position.
The time of the day will be displayed when the controller reaches the service position.
6 .
Maintenance
Mandatory:
Cleaning and maintenance shall take place at regular intervals in order to guarantee the proper
functioning of the complete system, and be documented in the Maintenance record book.
Mandatory:
respecting this may void the warranty.
7 .
Troubleshooting
Please follow this procedure for any technical support:
A
Collect the required information for a technical assistance request.
Product identification (see 2.1. Serial label location, page 5 and Original settings, page 2.
Error number displayed on the controller.
B
Contact your local dealer who installed this device (see contact details on last page).
Also call him if the water tastes salty, if the water is not softened or if there is no salt consumption.
Ref. MKT-UG-007 / D - 09.10.2020
3
;
3
by increments of 0.05 m
3
3
by increments of 0.1 m
3
3
by increments of 0.2 m
3
3
by increments of 0.5 m
for 3 seconds.
and
for 3 seconds during any regeneration cycle.
The maintenance and service operation must be done by qualified personnel only. Failure in
3
(12 increments);
(20 increments);
(10 increments);
(10 increments).
and
for 3 seconds.
Delayed regeneration
A
Press
The system will regenerate at the next time of
regeneration (2:00).
The regen dot blinks when delayed regeneration is on.
Note:
Press
User Guide 368 / 604-606
to display the value.
to set a delayed regeneration.
to disable the delayed regeneration.
7 / 40