BTL6-A/C/E/G500-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
4
Installation and connection (continued)
4.3

Floating magnets

The following must be observed when installing the
magnet:
To ensure the accuracy of the position measuring
system, the magnet is attached to the moving member
of the machine using non-magnetizable screws
(stainless steel, brass, aluminum).
The moving member must guide the magnet on a track
parallel to the transducer.
Ensure that the distance A between parts made of
magnetizable material and the magnet is at least
10 mm (see Figures 4-3 to 4-7).
Maintain the following values for distance B between
the magnet and transducer and for center offset C (see
Figures 4-3 to 4-7):
Type of magnet
Distance B
BTL5-P-3800-2
0.1...4 mm
BTL5-P-5500-2
5...15 mm
BTL5-P-4500-1
0.1...2 mm
BTL6-A-3800-2
4...8 mm
BTL6-A-3801-2
4...8 mm
The selected distance must stay constant over the entire measuring length.
1)
For optimum measurement results, a distance B of 6 to 8 mm is
2)
recommended.
Tab. 4-1:
Distance and offset for magnets (see Figures 4-3 to 4-7)
A
A
Fig. 4-3:
Dimensions and distances with BTL5-P-3800-2 magnet
A
A
Fig. 4-4:
Dimensions and distances with BTL5-P-5500-2 magnet
www.balluff.com
Offset C
1)
± 2 mm
± 15 mm
± 2 mm
± 5 mm
2)
± 5 mm
2)
C
C
A
A
Fig. 4-5:
Dimensions and distances with BTL6-A-3800-2 magnet
A
A
Fig. 4-6:
Dimensions and distances with BTL6-A-3801-2 magnet
Plug with
A
A
LED
4
Fig. 4-7:
Dimensions and distances with BTL5-P-4500-1
electromagnet (24 V/100 mA)
The measuring range is offset by 4 mm towards
the transducer plug (see Figure 4-7).
C
C
C