WARNING: NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR WHILE HOT!
Use only original equipment replacement parts. The
use of alternate or third party components can cause
unsafe operating conditions, and will void your war-
ranty.
Do not tamper with the unit. Have a competent ser-
viceman make any necessary adjustment or repairs.
We suggest following a maintenance schedule as fol-
lows:
FUEL TANK:
Flush every 200 hours of operation or as needed.
Do not use water to flush the tank. Use fresh #1-K
kerosene only.
FAN BLADES:
Blades should be cleaned at least once per heat-
ing season, depending on conditions. Remove all
accumulated dust and dirt with a damp cloth, tak-
ing care not to bend any of the fan blades. Be sure
fan blades are dry before re-starting the heater.
FUEL FILTER:
The Fuel Filter should be cleaned at least twice
per heating season by rinsing it in clean #1-K
kerosene. Contaminated fuel could make this nec-
essary immediately.
NOTE: To remove the filter from turn filter 90° counter-
clockwise.
SPARK PLUG:
Clean and re-gap every 600 hours of operation, or
replace as needed.After removing the Spark Plug,
clean the terminals with a wire brush. Re-gap the
terminals to 0.140" (3.5mm).
NEVER LEAVE HEATER UNATTENDED WHILE
BURNING OR WHILE CONNECTED TO A
FUEL SOURCE.
IMPROPER
MAINTENANCE
TO
POOR
PRODUCTION
14
CAN
COMBUSTION
AND
MAINTENANCE
Fuel Line
Gap (3.5 mm)
LEAD
SOOT
Siroco Fan
Motor
Fuel Filter
Fuel Tank
Spark Plug
Burner Head
Kerosene Portable Heaters Manual
Set Screw
Motor Shaft
Fan Blade
Ignitor Wire