GB
Introduction
Thank you for purchasing this Silverline tool. This manual contains information
necessary for safe and effective operation of this product. This product has
unique features and, even if you are familiar with similar products, it is necessary
to read this manual carefully to ensure you fully understand the instructions.
Ensure all users of the tool read and fully understand this manual.
Description of Symbols
The rating plate on your tool may show symbols. These represent important
information about the product or instructions on its use.
Wear hearing protection
Wear eye protection
Wear breathing protection
Wear head protection
Wear hand protection
Read instruction Manual
DO NOT use in rain or damp environments!
Risk of electrocution
Danger of toxic welding fumes
Danger of ultraviolet radiation
Danger hot Surfaces
Caution!
Danger of Fire
Class I construction (protective earth)
Conforms to relevant legislation and safety standards.
Environmental Protection
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist. Check
with your local authority or retailer for recycling advice.
4
Original Instructions
Technical Abbreviations Key
V
Volts
~ ,AC
Alternating current
A, mA
Ampere, milli-Amp
Ø
Diameter
Hz
Hertz
,DC
Direct current
W, kW
Watt, kilowatt
Specification
Input voltage: .................................................... 230/400V~ 50Hz
Mains connection: ..................................................................32A
Input current: ...................... 230V: 36.8A (peak), 10.9A (effective)
400V: 32.8A (peak), 7.5A (effective)
Efficiency: .............................................................................80%
Output current range: ..................................................... 60-250A
Rated duty cycle:................................ 10% @ 250A, 60% @ 60A
No load output voltage: .......................................................... 48V
Output voltage: ......................................22.4V(60A), 30.0V(250A)
Electrode rod size: ...................................................2.0 – 5.0mm
Insulation class: .........................................................................H
Ingress protection: .............................................................. IP21S
Welding thickness range (steel): ............................... 2.5 - 10mm
Internal fuse rating: ................................................................32A
Protection class: .....................................................................
Torch cable length:...............................................................2.0m
Earth cable length: ...............................................................1.5m
Power cable length: .............................................................2.0m
Dimensions (H x L x W): ............................... 265 x 470 x 315mm
Weight: ............................................................................. 22.5kg
As part of our ongoing product development,