Controlador Y Tableros De Extensión 1-16 - DKS 1833 Manual Del Propietário

Sistemas programables de control de entrada y de acceso teléfonico para uso con pc
Tabla de contenido

Publicidad

2.3.3
Controlador Y Tableros De Extensión 1-16
30 Series Controller to 2351-010 Expansion Boards 1-16
Detail Wiring
1
1
RS 232
Elevator
2
2
Connection
Control
3
3
4
12
5
6
+ 12 VDC
14
13
COMMON
12
DATA 1
DATA 0
11
+ 12 VDC
10
COMMON
9
DATA 1
8
DATA 0
7
6
5
4
NEG 12 VDC BATT INPUT
3
POS 12 VDC BATT INPUT
Relay 0
2
1
13
1 2 3
4
6
13
14
15
16
17
18
19
C.O.
PHN
2
1
Central Office phone line - touch tone, loop start.
1
A switch closure across terminals 4 & 6 will activate relay 1
2
for its programmed strike time.
Battery Backup - separate batteries required for phone
3
system and weigand terminals.
16 Volt, 20 VA UL Listed Transformer.
4
7
GRN
WHT
BLK
RED
BLK
WHT
GRN
6
11
7
RED
BLK
WHT
GRN
GRN
16 VAC
WHT
OUTPUT
BLK
RED
+
3
16 VAC
PWR
INPUT
8
4
To Main
Door / Gate
6
+
3
5
20
16 VAC
6
PWR
INPUT
7
5
4
8
9
10
11
12
13
LOCK
PWR
10
CARD
DOOR
RDR
LOCK
2351-010
P2
P1
6
5
7
6
BRN
8
9
RED
10
BLK
7
WHT
8
GRN
9
13
BLU
17
12
16 VAC
13
PWR
14
INPUT
4
LOCK
PWR
10
CARD
DOOR
RDR
LOCK
2351-010
P2
P1
6
5
7
6
BRN
8
9
RED
10
BLK
7
WHT
8
GRN
9
13
BLU
17
12
16 VAC
13
PWR
14
INPUT
4
For 1837, use 16 Volt, 40 VA UL Listed Transformer.
Belden 9931 or Equivalent. Shield runs continuous. Float the shield, do not
connect shield to 2351-010 board common.
Belden 9418 or Equivalent. If reader is lighted, Belden 9931 can be used to
provide extra wires for light power.
Aux power transformer must be connected. Otherwise, RS232, elevator control and
weigand inputs will not function.
Communication cable to additional boards is connected in parallel. Allows "teeing" of
communication cable for optimal cable routing.
Power for door strikes or magnetic locks is not provided by the system. It must be
provided by an external power supply.
No connection at controller.
See Dwg No. M1835-065-5 for
detail.
Title:
EARTH Ground.
Date:
24
LOCK
PWR
10
7
CARD
DOOR
RDR
LOCK
2351-010
P2
P1
GRN
6
5
WHT
7
6
BLK
BRN
8
RED
9
RED
10
BLK
7
WHT
8
GRN
9
13
BLU
17
12
16 VAC
13
PWR
14
INPUT
4
To
Boards
9-16
9
LOCK
PWR
10
CARD
7
RDR
DOOR
LOCK
2351-010
P2
P1
GRN
6
5
WHT
7
6
BLK
BRN
8
RED
9
RED
10
BLK
7
WHT
8
GRN
9
13
BLU
17
12
16 VAC
13
PWR
14
INPUT
To
Boards
3-8
9
DOORKING, INC., INGLEWOOD, CA 90301
Detail Wiring - 30 Series Controller to 2351-010
Expansion Boards 1-8
A
3/03
Dwg. No.
M1835-065-4
Rev.
4

Publicidad

Tabla de contenido
loading

Productos relacionados para DKS 1833

Este manual también es adecuado para:

183418351837

Tabla de contenido