TECHNICAL DATA

Voltage IN
Voltage OUT
Power
Current (max)
Torque
Motor Speed
Travel Speed
Duty Cycle
Working Temperatur Range
Protection Class
Degree of Protection
Weight
approx. Gate Length
Max. Gate weight at
max. length (incl. 20%
reserve)

INITIAL OPERATION

Check gate functionality manually when the drive has been
disengaged. Electrical operation is only possible with the control unit
that is supplied as standard.
Electrical connections: See control unit instructions.
Always ensure that the mechanical and electrical safety requirements
relevant to the given system are complied with. fig. 8

MAINTENANCE WORK

The drive mechanics are maintenance-free. Check at regular
intervals (monthly) that the gate hardware and the drive are all firmly
in place. Disengage the drive and check gate functionality. Only an
easy-running gate will work well with a drive. A drive is no substitute
for a poorly functioning gate.
A sliding gate can also be secured by implementing on-site
measures (fence, wall, etc.). See fig. 9.
SLY300-24
220 - 240
VAC
VDC
24
W
40
5
A
10
Nm
2500
RPM
14
cm/s
50
Zyklen/h
-20°C/+55°C
°C
I
I
44
IP
8
Kg
m
5
300
Kg
© Chamberlain GmbH 2009
SLY500-24
220 - 240
24
60
6
15
2200
12
50
-20°C/+55°C
I
44
8
8
500
D e c l a r a t i o n o f C o n f o r m i t y
Automatic Gate Opener Models SLY300-24, SLY500-24 Series
are in conformity to the applicable
sections of StandardsEN300220-3 • EN55014 • EN61000-3 • EN60555, EN60335-1 • ETS
300 683 • EN60335-1: 2002 • EN60335-2-103: 2003 • EN55014-1: 2000 + A1 + A2 •
EN55014-2: 2001 • EN61000-3-2: 2000 • EN61000-3-3: 1995 + A1 • EN 301 489-3,
V1.3.1 • EN 300 220-3 V1.1.1 • EN13241-1
per the provisions & all amendments
of the EU Directives .............................................2006/95/EC, 2004/108/EC, 1999/5/EG
D e c l a r a t i o n o f I n c o r p o r a t i o n
Automatic Gate Opener Models , when installed and maintained according to all the
Manufacturer's instructions in combination with a Gate, which has also been installed and
maintained according to all the Manufacturer's instructions, meets the provisions of EU
Directive 89/392/EEC and all amendments.
I, the undersigned, hereby declare that the equipment
specified above and any accessory listed in the manual
B.P.Kelkhoff
Manager, Regulatory Affairs
Chamberlain GmbH
D-66793 Saarwellingen
August, 2008
conforms to the above Directives and Standard
s.

Publicidad

loading

Este manual también es adecuado para:

Sly500-24