LOOP DETECTOR (OPTIONAL)
DIP "OPEN/PED" must be on.
Loop detectors react to metal and the most common use is for cars
or trucks but not for bikes or pedestrians.
Exit loop / Gate Opening Loop
An exit loop is behind the gate and opens the gate when closed,
keeps it open or re-opens the gate.
The DIP "OPEN/PED" must be on.
The gate requires installed photocells and timer to close activated.
In addition, the feature "Fast closing" can be activated.
Refer to section "Description of Push Buttons P1, P2, P3 & RESET".

DIP SWITCH SETTINGS

RADIO PROGRAM
The DIP "RADIO PROGRAM" is required to program remote controls.
For programming procedure please refer to the respective section in this manual.
OFF:
No programming of remote controls possible
ON:
Programming of remote controls possible
Important: Always switch off DIP "RADIO" after use!
STOP/8,2 KOhm
Defi nes whether the terminal STOP/8,2KOhm is used in emergency
stop mode or safety edge mode. With an emergency stop any
movement of the gate will be stopped. When used for a safety edge
the gate reverses for aproximately 20 cm.
OFF:
Factory setting is 8,2KOhm. Safety edge or 8.2kOhm resistor is required.
ON:
Emergency stop required. In this case the resistor must be removed and
replaced by the switch or a switch circuit.
OPEN/PED
Defi nes if a key switch opens the gate completely or partially.
Note: If the DIP "OPEN/PED" is on and timer to close is activated as
well, the functionality of the terminals "key symbol" and "COM"
changes. See section "Loop Detector" above.
OFF:
opens partially (ca. 100 -150 cm)
ON:
opens completely
PHO 2 MODE
Defi nes whether the second photocell is active in closing or in opening.
OFF:
active in closing
ON:
active in opening
WIRE JUMPER (DIP FIX):
OBSTACLE
Factory-equipped with wire jumper. Disabling (opening) increases the
operating power at the control.
CAUTION: If the jumper is disabled, the door system must be secured
with additional safety devices (safety edge, etc.).
SPEED
Factory-equipped with wire jumper. Disabling (opening) increases the
operating speed of the gate.
CAUTION: If the jumper is disabled, the door system must be secured
with additional safety devices (safety edge, etc.).
NO
Model
203292
Wire jumper
9/14 en