60
3.2 Input, Output, and Measurement Specifications
Range
(Accuracy
Range)
20.00 mA
(1.00 mA to
20.00 mA)
200.0 mA
(18.0 mA to
200.0 mA)
2.000 A
(0.180 A to
2.000 A)
20.00 A
(1.80 A to
20.00 A)
60.0 A
(18.0 A to
60.0 A)
Guaranteed
Resolution
accuracy
frequency range
45 Hz f 66 Hz
0.01 mA
30 Hz f < 45 Hz
66 Hz < f  400 Hz
45 Hz f 66 Hz
0.1 mA
30 Hz f < 45 Hz
66 Hz < f 400 Hz
45 Hz f 66 Hz
0.001 A
30 Hz f < 45 Hz
66 Hz < f 400 Hz
45 Hz f 66 Hz
0.01 A
30 Hz f < 45 Hz
66 Hz < f 400 Hz
45 Hz f 66 Hz
0.1 A
30 Hz f < 45 Hz
66 Hz < f 400 Hz
HIOKI FT6380B983-00
Accuracy
(Intrinsic uncertainty A)
Filter off
Filter on
±2.0% rdg
±2.0% rdg
±0.05 mA
±0.05 mA
±2.5% rdg
±0.05 mA
±2.0% rdg
±2.0% rdg
±0.5 mA
±0.5 mA
±2.5% rdg
±0.5 mA
±2.0% rdg
±2.0% rdg
±0.005 A
±0.005 A
±2.5% rdg
±0.005 A
±2.0% rdg
±2.0% rdg
±0.05 A
±0.05 A
±2.5% rdg
±0.05 A
±2.0% rdg
±2.0% rdg
±0.5 A
±0.5 A
±2.5% rdg
±0.5 A
--
--
--
--
--