a. Press the
or
b. The"RTS" is fixed and cannot be changed; this setting corresponds to the temperature that is stored in the
electronic unit's memory when it is in "READY TO SERVE" mode.
15. Press the
key to confirm; the display will show the fourth option of the SERVICE submenu.
The display shows the time period in which the electronic unit, by controlling the temperature decrease, decides
when to change from "WAIT PLEASE" to "READY TO SERVE" mode. Although "READY TO SERVE" mode can be seen,
the solenoid valve is still active, because it is controlled by "EV OFF TIME", the fifth option of the submenu. In "EV
OFF TIME = RTS TIME" mode, the machine passes from "WAIT PLEASE" to "READY TO SERVE" and the deactivation
of the solenoid valve coincide. The default value is RTS TIME= 10min.
a. Press the
or
16. Press the
key to confirm; the fifth option of the SERVICE submenu will appear on the display.
The display shows the time period in which the electronic unit, by controlling the temperature decrease, decides
when to deactivate the solenoid valve and when to product maintenance. The default setting is: EV OFF TIME=
10min
a. Press the
or
17. On pressing the confirm key
18. Press the
key to exit the menu.
Examples of settings
V1=70rpm
T1=-3,5°C
25.7°F
When the SERVICE submenu is set according to the above table, the machine will function as follows:
• When passing from "Motor On" to "Soft Mode WAIT PLEASE" mode, the augers turn at 70rpm, as long as the
temperature shown on the TANK TEMPERAT. screen is warmer than -3,5°C/25.7°F (e.g. -3,0°C/26.6°F);
• When the product temperature reaches -3,5°C/25.7°F, the speed reduces to 50rpm. This is valid if the display still
reads "Soft Mode WAIT PLEASE";
• When the temperature reaches -4,5°C/23.9°F, the speed decreases to 40rpm. This speed will be maintained even
if the display reads "Soft Mode READY TO SERVE" and will do so for the entire maintenance period of the product.
The same increases to 70rpm if the tank is dispensing. It will then return to 40rpm, 20 seconds after the tap is
closed.
During the "WAIT PLEASE" to "READY TO SERVE" phase the V3 speed predominates over the, V1 and V2
speeds. Therefore, if a specific product shows "READY TO SERVE" at -3,4°C/25.9°F, the velocity will reduce
from 70rpm to 40rpm, skipping the 50rpm stage.
keys to change the V3 "20 min. / max 70 in steps of 1rpm"
RTS TIME
10min.
keys to change the 10 "03 min. / max 20 in steps of 1min." Settings.
EV OFF TIME
10min.
keys to change the 10 "min. 03 / max 20 in steps of 1min." settings.
the control panel will return to the SERVICE screen.
> SERVICE
V2=50rpm
V3=40rpm
T2=-4,5°C
23.9°F
RTS time= 10'
EV off time=10'
- 32 -